期刊文献+

Study on in Vitro Degradation of Sutures for Decomposable Esophageal Stent

Study on in Vitro Degradation of Sutures for Decomposable Esophageal Stent
下载PDF
导出
摘要 PLLA and PGLA sutures for decomposable esophageal stent were investigated in phosphate buffer solution (PBS) (pH=7.4) at 37℃ for a period of 8 weeks. In vitro degradation was studied by determining the change of weight loss, pH value, intrinsic viscosity, tensile strength, orientation degree, degree of crystallinity, melting point and surface morphology of the suture samples. The results showed that all properties of PLLA sutures had no obvious changes, however, the properties of PGLA sutures all changed significantly. The pH value, intrinsic viscosity, tensile strength, orientation degree and degree of crystallinity decreased gradually, and the weight loss of PGLA sutures increased with the degradation time. At 6th week, tensile strength of PGLA sutures nearly reached 0, and weight loss approached to 70% at 8th week. The results of DSC showed that melting point of crystalline region of PGLA sutures substantially remained unchanged and melting heat enthalpy increased gradually during in vitro degradation, and the new ordered regions appeared in the amorphous area. The results of SEM showed that surface coating of PGLA sutures spalled initially, and then the sutures occured transverse rupture. Therefore, PGLA suture is suitable to prepare decomposable esophageal stent to expand benign esophageal stenosis or stricture, but stent prepared by PLLA suture is not appropriate for the treatment of benign esophageal stenosis because it is decomposed for more than 2 months. PLLA and PGLA sutures for decomposable esophageal stent were investigated in phosphate buffer solution (PBS) (pH=7.4) at 37 ℃ for a period of 8 weeks. In vitro degradation was studied by determining the change of weight loss, pH value, intrinsic viscosity, tensile strength, orientation degree, degree of crystallinity, melting point and surface morphology of the suture samples. The results showed that all properties of PLLA sutures had no obvious changes, however, the properties of PGLA sutures all changed significantly. The pH value, intrinsic viscosity, tensile strength, orientation degree and degree of crystallinity decreased gradually, and the weight loss of PGLA sutures increased with the degradation time. At 6th week, tensile strength of PGLA sutures nearly reached O, and weight loss approached to 70% at 8th week. The results of DSC showed that melting point of crystalline region of PGLA sutures substantially remained unchanged and melting heat enthalpy increased gradually during in vitro degradation, and the new ordered regions appeared in the amorphous area. The results of SEM showed that surface coating of PGLA sutures spalled initially, and then the sutures occured transverse rupture. Therefore, PGLA suture is suitable to prepare decomposable esophageal stent to expand benign esophageal stenosis or stricture, but stent prepared by PLLA suture is not appropriate for the treatment of benign esophageal stenosis because it is decomposed for more than 2 months.
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2012年第2期73-79,共7页 中国生物医学工程学报(英文版)
基金 Shandong Provincial Science and Technology Development Program grant number: 2009GG10002077
关键词 体外降解 缝合线 可分解 食管 支架 磷酸盐缓冲溶液 拉伸强度 PLLA PLLA PGLA suture in vitro degradation decomposable esophagealstent
  • 相关文献

参考文献4

二级参考文献9

共引文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部