期刊文献+

闭式带压回收技术在尿素装置蒸汽冷凝液回收系统的应用 被引量:1

Application of Closed Recovery Technology with Pressure in Steam Condensate Recovery System of Urea Plant
下载PDF
导出
摘要 针对水溶液全循环法尿素装置蒸汽冷凝液的敞口式回收方式存在热能损失的问题,实施了以闭式带压回收方式替代敞口回收方式的节能技术改造。技改结果表明:节煤1 053 t/a,节能收益为63万元/a。 In allusion to the problem that there was loss of heat energy in the open recovery mode of steam condensate in the urea plant with water solution full circulation method, technical reformation aimed at energy saving has been executed by closed recovery mode with pressure having replaced the open recovery mode. Technical reformation result indicates, 1 053 t/a of coal is saved , energy saving benefit is 630 000 Yuan RMB per year.
出处 《化肥设计》 CAS 2012年第6期44-45,48,共3页 Chemical Fertilizer Design
关键词 尿素装置 蒸汽冷凝液 敞口式回收 闭式带压回收 凝结水回收器 节能减排 urea plant steam condensate open recovery closed recovery with pressure condensate recoverer energy saving and discharge reducing
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部