期刊文献+

4-氯酚在聚乙烯吡咯烷酮修饰碳糊电极上的电化学行为研究

Electrochemical behaviors of 4-bhlorophenol at a polyvinylpyrrolidone modified carbon paste electrode
下载PDF
导出
摘要 研究了4-氯酚在聚乙烯吡咯烷酮(PVPr)修饰碳糊电极上的电化学行为,实验结果表明4-氯酚在修饰电极表面于0.53 V(vs.Ag-AgCl)处有一灵敏的氧化峰。采用1∶1(质量比)的PVPr和超导电炭黑(0.2 g)滴加650μL石蜡油制作的修饰碳糊电极在0.1 mol.L-1的磷酸盐缓冲液(pH=7.12)中用差示脉冲伏安法测定4-氯酚,其浓度在0.5-100μmol.L-1范围内和峰电流呈良好线性关系,检出限为0.05μmol.L-1。 Electrochemical behaviors of 4-chlorophenol at polyvinylpyrrolidone (PVPr) modified carbon paste electrode are studied. The result shows that 4-chlorophenol has a sensitive oxidation peak at 0.53 V (vs. Ag/ AgCl). The modified carbon paste electrode was produced by PVPr and super conductive carbon black (0.2 g) at a mass ratio of 1:1. 650μL paraffin oil was added as the binder. 4-chlorophenol was detected by this modified electrode in 0.1 mol-L-1 phosphate buffer (pH 7.12) by differential pulse stripping voltammetry. The oxidation currents of 4-chlorophenol were in a good linear relationship with the concentration of the analyte in the range of 9.5-100μmol-L-1 and a detection limit of 0.05 μmol.L-1 (S/N=3).
出处 《苏州科技学院学报(自然科学版)》 CAS 2012年第4期21-24,30,共5页 Journal of Suzhou University of Science and Technology (Natural Science Edition)
基金 国家自然科学基金资助项目(20905055) 江苏省青蓝工程青年骨干教师项目
关键词 聚乙烯吡咯烷酮 4-氯酚 碳糊修饰电极 polyvinylpyrrolidone 4-chlorophenol modiiied carbon paste electrode
  • 相关文献

参考文献9

  • 1Keith L H. Compilation of EPA's Sampling and Analysis Methods[M]. 2th ed. New York :Lewis Pubb, 1996:389.
  • 2Glaze W, Kang J, Chapin D. Priority pollutants: A prospective view[J]. Environ Sci Technol, 1979,13:416-424.
  • 3Blau P J, Budinski K G. Development and use of ASTM standards for wear testing[J]. Wear, 1999,225 : 1159-1170.
  • 4Peng J F,Liu J F,Hu X L,et ol. Direct determination of chlorophenols in environmental water samples by hollow fiber supported ionic liquid membrane extraction coupled with high-performance liquid chromatography[J]. J Chromatogr A, 2007,1139:165-170.
  • 5Rogers K R, Becker J Y, Wang J,et al. Determination of phenols in environmentally relevant matrices using a liquid chromatographic system with an enzyme-based biosensor[J]. Field Anal Chem Technol, 1999,3 : 161-169.
  • 6Dall'Orto V D,Danilowicz C ,Sobral S,et al. Liquid chromatography/electrochemical detection of phenols at a Poly [Ni-(Protoporphyrin IX)] chemically modified electrode[J]. Anal Chim Acta, 1996,336:195-199.
  • 7EI-Kosasy A M,Riad S M,Abd E1-Fattah LE,et a/. Novel poly (vinyl chloride) matrix membrane electrodes for the determination of phenolic pollutants in waste water[J]. Water Research,2003,37 : 1769-1775.
  • 8Anandhakumar S, Chandrasekaran M,Noel M. Anodic oxidation of chlorophenols in micelles and micro emulsions on glassy carbon electrode: the medium effect on electroanalysis and electrochemical detoxification[J]. J Appl Electrochem, 2010,40:303-310.
  • 9Carpenter A,Siggia S,Carter S. Separation and/or concentration of phenolic materials from dilute aqueous solutions [J]. Anal Chem, 1976,48: 225-228.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部