期刊文献+

提高客人进入酒店空置客房舒适度的温控措施

Temperature Control Measures to Improve Thermal Comfort in Vacant Guest Rooms in a Hotel
下载PDF
导出
摘要 为确保客人对入住客房舒适度要求,某酒店采取空置客房室内温度设定在22~25℃的温控措施,不仅不能满足客人对舒适度的要求而且导致空调系统能耗较高。在对客人进入空置客房(以空调系统末端不工作为前提)的初始热感觉、初始满意度、期望舒适温度、期望获得舒适温度的时间进行调查分析的基础上,对提高客人进入空置客房舒适度的温控措施进行探讨。 The indoor temperature in vacant guest rooms in a hotel is controlled at 22 to 25℃ in order to ensure the thermal comfort requirement of guest rooms, which not only can not meet the guest re- quirements for thermal comfort but results in high energy consumption of air-conditioning system. Based the investigation and analysis on the initial thermal feeling, initial satisfaction level, expected comfortable temperature and expected time for comfortable temperature ( no operation of end equipment of air-condi- tioning system), the temperature control measures to improve the thermal comfort in vacant guest rooms are discussed.
出处 《煤气与热力》 2012年第12期7-8,35,共3页 Gas & Heat
关键词 舒适度 空置客房 空房模式 迎宾模式 温控措施 thermal comfort vacant guest room vacant room mode welcome mode tem- perature control measure
  • 相关文献

参考文献5

二级参考文献16

共引文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部