摘要 目的探讨踝关节有限切开结合微创内固定疗胫骨Pilon骨折的效果。方法 2007年1月~2011年12月,闭合性胫骨Pilon骨折58例,按Rüedi-Allgwer分型:Ⅰ型24例,Ⅱ型21例,Ⅲ型13例。采用踝关节有限切开技术与微创内固定治疗。结果术后随访2~48个月,平均19.5月。按Mazur方法进行功能评分,优48例,良6例,可4例,优良率93%(54/58)。结论踝关节有限切开复位结合微创内固定效果良好,是治疗胫骨Pilon骨折的可选方法之一。 Objective To evaluate the efficacy of limited incision combined with minimally invasive percutaneous osteosynthesis for tibia1 Pilon fractures. Methods From January 2007 to December 2011, totally 58 patients with Pilon fractures of the tibia received limited incision combined with percutaneous osteosynthesis in our hospital. According to Rtledi-Allgw6er Pilon fracture classification, 24 of the patients were type I , 21 type II , and 13 type III. Results The patients were followed up for 2 - 48 months (mean, 19.5 months). According to Mazur' s criteria, the surgical result was excellent in 48 patients, good in 6 patients and fair in 4. No poor result was found. Conclusion Limited incision combined with minimally invasive percutaneous osteosynthesis is an optimal approach for tibial Pilon fractures. We recommend it as a routine therapy.
机构地区 解放军第
出处 《中国微创外科杂志》 CSCD 2012年第12期1115-1118,共4页 Chinese Journal of Minimally Invasive Surgery
关键词 微创技术 PILON骨折 骨折内固定术 外科手术 Minimally invasive Pilon fracture Fracture fixation Surgery
  • 相关文献

参考文献6

二级参考文献16

  • 1陈凯,杨长伟,王秋根.锁定加压接骨板应用原则及注意事项[J].国际骨科学杂志,2007,28(3):138-139. 被引量:46
  • 2Zohman G L.Distal tibia fracture opinion:open reduction and internal fixation[J].J Orthop Trauma,2006,20(1):70-72.
  • 3Wenda K,Runkel M,Degreif J,et al.Minimally invasive plate fixationin femoral shaft fractures[J].Injury,1997,28(Suppl 1):A13-19.
  • 4Johner R,Wruhs O.Classification of tibial shaft fractures and correlation with results after rigid internal fixation[J].Clin Orthop Relat Res,1983,(178):7-25.
  • 5Krackhardt T, Dilger J, Flesch 1, et al. Fractures of the distal tibia treated with closed reduction and minimally invasive plating. Arch Orthop Trauma Surg,2005,125 ( 2 ) :87 - 94.
  • 6Borg T, Larsson S, Lindsjo U. Percutaneous plating of distal tibial fractures. Preliminary results in 21 patients, lniury, 2004,35 ( 6 ) : 608 -614.
  • 7Redfem DJ, Syed SU, Davies SJM. Fractures of the distal tibia: minimally invasive plate osteosynthesis. Injury ,2004,35 (6) :615 - 620.
  • 8Borrelli J Jr, Priekett W, Song E, et al. Extraosseous blood supply of the tibia and the effeets of different plating teehniques: a human eadaverie study. J Orthop Trauma, 2002,16(10) :691 -695.
  • 9Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws. J Orthop Trauma, 2004,18 (8) :488 -493.
  • 10Wagner M. General principles for the clinical use of the LCP. Injury ,2003,34 ( Suppl 2 ) ..$31 - $42.

共引文献45

同被引文献21

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部