摘要 目的探讨亚甲蓝光化学法(MBP)病毒灭活血浆在1年保存期内不同时间点成分的质量变化。方法 30人份全血制备新鲜血浆和病毒灭活新鲜血浆,同一人份制备的新鲜血浆分两组留样,一组为不灭活的新鲜血浆,另一组为病毒灭活后新鲜血浆,分别检测每组样本保存不同时间后的凝血因子活性和纤维蛋白原(Fib)含量的变化。结果病毒灭活前后FⅡ:C、FⅤ:C、FⅦ:C、FⅧ:C、FⅨ:C、FⅩ:C的含量比较发现,灭活前后血浆凝血因子差异无统计学意义(P>0.05),Fib的含量在病毒灭活前后有差异。同时还发现,FⅡ:C、FⅤ:C、FⅦ:C和FⅩ:C的含量在冻存期间呈缓慢下降趋势,在冻存12个月时含量还能维持在70%以上。而FⅧ:C和FⅨ:C在冻存后含量迅速下降,在冻存12个月时含量仅维持在30%~50%。Fib在冻存期间的含量也呈逐渐下降趋势,在冻存12个月时含量约维持在60%。结论作者认为应加强对病毒灭活血浆质量标准及血制品冻存等操作规程的研究,在保证输血安全的同时应确保输注血浆成分的疗效。 Objective To observe the effects of methylene blue photochemical(MBP) virus inactivation to blood plasma components at different time points during one year. Methods A total of 30 blood samples were randomly selected. Fresh plasma from whole blood was prepared two parts,one was reserved,another was sterilely connected with MBP virus inactivation. The amounts of FⅡ :C,FⅤ :C,FⅦ :C,FⅧ :C,FⅨ :C,FⅩ :C and the content of fibrinogen(Fib) were detected in the plasma samples exposure MBP or not at different time points. Results The amounts of FⅡ C,FⅤ : C, FⅦ : C, FⅧ : C, FⅨ : C, F Ⅹ: C were not significantly different before and after exposure MBP. However, the content of Fib was significantly lower under exposure compared with non-exposure. At the mean while, the amounts of F Ⅱ : C, F Ⅴ : C, F Ⅶ: C, F Ⅹ : C were decreased slowly and maintained about 70 % during 12 months. However,the amounts of FⅧ :C and FⅨ ..C were decreased sharply and only maintained only 30% to 50 %fro during 12 months. The content of Fib was only maintained 60% during 1 year storage. Conclusion Ensuring the safety of blood transfusion and the curative effects of plasma components are needed to strengthen the study for the virus inactivation plasma quality standards,hematic products frozen storage and operation procedures.
出处 《检验医学与临床》 CAS 2012年第24期3043-3044,共2页 Laboratory Medicine and Clinic
基金 国家卫生公益性行业科研专项(200902008) 苏州市科技计划项目(SYS201061)
关键词 亚甲蓝光化学法 血浆 凝血因子 blue photochemical blood plasma blood coagulation factor
  • 相关文献

参考文献4

  • 1Politis L, Kavallierou S, Hantziara P, et al. Quality and safety of fresh-frozen plasma inactivated andleucoreduced with the Theraflex methylene blue system including the Blueflex filter : 5 years' experience[J]. Vox Sang, 2007,92 (4) :319-326.
  • 2Mohr H, Knuver-Hopf J, Gravemann U, et al. West Nile virus in plasma is highly sensitive to methylene blue-light treatment[J]. Transfusion, 2004,44 (6) : 886-890.
  • 3张文福,袁庆霞,王宏霞,李成文,刘育京.亚甲蓝光敏法对人血浆中病毒的灭活研究[J].中国消毒学杂志,1999,16(2):65-68. 被引量:11
  • 4李忠平.临床输用血浆病毒灭活的研究进展[J].国外医学(输血及血液学分册),2001,24(2):157-159. 被引量:8

二级参考文献13

  • 1Klein HG, Doda RY, Dzik WH, et al. Transfusion, 1998,38:102
  • 2Wagner SJ, Skripchenko O, Robinette D, et al. Transfusion, 1998,38:729
  • 3Margolis- Nunno H,Bardossy L,Robinson R,et al.Transfusion,1997,37: 889
  • 4Lavie G,Mazut Y,Lavie D,et al. Transfusion,1995,35:392
  • 5Burnouf - Radosevich M, burnouf T, Huart J J, et al. Rev Fr Transfus Hemobil, 1993,36: 93
  • 6Horowitz B,Bonomo R,Prince AM,et al. Blood,1992,79:826
  • 7Ness PM. Transfusion, 1999,39:1027
  • 8Pohl U, Mohr H. Poster presentation at the 24th ISBTCongress,Makuhari Messe,Japan,April, 1966
  • 9Lambercht B. Vox Sang,1991,60:207
  • 10Ann Catrine Simonsen,Henning S~rensen. Vox Sang,1999,77:210

共引文献17

同被引文献7

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部