期刊文献+

合成回路汽包加药管线泄漏原因分析及在线处理

ANALYSIS OF CAUSES FOR LEAKAGE ON CHEMICAL-FEED LINE OF STEAM DRUM IN SYNTHESIS LOOP AND ON-LINE TREATMENT
下载PDF
导出
摘要 介绍合成装置合成回路汽包加药管线的泄漏处理措施,根据不停车带压堵漏夹具方式的特点,采用双夹具串联的技术手段成功堵漏,为高温高压管线的泄漏处理及相关问题提供了很好的解决措施。 Measures taken for the leakage on chemical-feed line of steam drum in synthesis loop ofammonia plant are introduced and based on the features of leaking stoppage fixture at pressure with no shut- down a double fixture in series technology is used and leakage stoppage is successful and this has provided a good solving measure in any leakage treatment in line of high-temperature and pressure.
出处 《大氮肥》 CAS 2012年第6期371-373,376,共4页 Large Scale Nitrogenous Fertilizer Industry
关键词 汽包加药管线 泄漏 高温高压 在线处理 chemical-feed line of steam drum leakage high-temperature and high-pressure on-line treatment
  • 相关文献

参考文献2

  • 1董定元,苏学仕.金属管焊接[M].北京:机械工业出版社,1997:167-180.
  • 2李亚江.焊接材料的选用[M].北京:化学工业出版社,1990:170-180.

共引文献5