摘要 浙江善高化学有限公司为了提高35 kV变配电系统的运行可靠性,结合变电所的运行现状,对其进行了自动化改造,将原变电所各种分立元件组成的各类继电器保护装置改为微机保护装置。对改造的35 kV变配电系统的具体构成、系统的自动化改造、各种保护功能的调试以及后台监控系统的设计进行了介绍。系统运行结果表明:改造后的系统能提高各种保护的精确度和可靠性;系统改造不仅提高了系统供电的可靠性,而且节约了人力,节省了运营成本。 In order to improve the operating reliability of the 35 kV electric transforming and distributing system, Zhejiang Gala Chemical Corp. combined the substation operation situation and carried on automation transformation. Various types of relay protection composed of separate components were transformed into the micro-computer protecting device. The improved 35 kV system architecture, system automatic transforming, the protecting functions adjusting and background monitoring system design were introduced. The operation indicated that the transformation enhanced the accuracy and reliability of the system protection, and not only improved power supply reliability but also saved manpower and reduced running cost.
作者 蒋中红
出处 《湖南工业大学学报》 2012年第5期56-61,共6页 Journal of Hunan University of Technology
关键词 35 kV高压系统 监控系统 自动化改造 35 kV high pressure system monitoring system automation transformation
  • 相关文献

参考文献6

二级参考文献19

共引文献25

同被引文献12

  • 1庞国栋.220KV变电站接地网的设计[J].内蒙古石油化工,2012,38(12):95-99. 被引量:2
  • 2水利电力部西北电力设计院.电力工程电气设计手册1:电气一次部分[M].北京:中国电力出版社,1989:907-913.
  • 3Tang Bin, Sun Xu, Zou Jiayong. Overview of Method for Reducing Grounding Resistance of Substation Grounding System[C]//Proceedings of the 2015 International Symposium on Computers & Informatics. IS. 1.] : Atlantis Press, 2015: 35-41.
  • 4He Jinliang, Zeng Rong, Gao Yanqing, et al. Seasonal Influences on Safety of Substation Grounding System[J]. PowerDelivery, IEEE Transactions on, 2003, 18(3) : 788-795.
  • 5中国电力企业联合会.GB/T50065-2011交流电气装置的接地设计规范[S].北京:中国计划出版社,2001:28-31.
  • 6Chen Wenguang, Bi Ruyu, Wang Jian, et al. Review of Grounding Grids Corrosion Diagnosis[J]. International Journal of Computer and Electrical Engineering, 2013, 5 (3) : 309-312.
  • 7杨晓雄,彭敏放,苗文华,刘振强.发变电站接地网优化设计[J].电力系统及其自动化学报,2010,22(4):45-48. 被引量:16
  • 8廖辉.浅谈110kV变电站接地网优化研究[J].黑龙江科技信息,2010(34):29-29. 被引量:3
  • 9邵阿红,叶永卫,田二明.变电站接地网降阻措施研究[J].重庆工商大学学报(自然科学版),2012,29(4):96-100. 被引量:4
  • 10李谦,文习山,肖磊石.土壤特性对变电站接地网特性参数影响的数值分析[J].高电压技术,2013,39(11):2656-2663. 被引量:43

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部