摘要 目的探讨颈动脉三维对比增强磁共振血管成像(3DCE—MRA)技术的规范。方法回顾性分析20例患者颈动脉3DCE—MRA的参数设置、实际操作和图像质量。结果不同对比剂注射方法、扫描方式、对比剂速率,以及是否使用生理盐水对图像质量的影响有显著差异。结论运用高压注射器注射对比剂、采用透视触发技术(主动脉弓显影至最亮时启动扫描)、维持对比剂速率2.0—3,0mL/s、使用生理盐水维持团注,可提高3DCE—MRA的图像质量。 Objective To explore the standardization of carotid three dimensional contrast enhanced magnetic resonance angiography (3D CE - MRA ) technology. Methods The parameter setting, actual operation and image quality of 20 patients with carotid artery 3D CE -MRA were retro- spectively analyzed. Results The image quality was affected significantly by different injection meth- ods of contrast agent, scanning mode, injection speed of contrast agent and use or not use of physiolog- ical saline. Conclusion Application of high pressure injector and perspective trigger technology ( start scanning when the aortic arch developing to the brightest) , maintenance of injection speed within 2.0 - 3.0 mL/s and maintaining group injection by normal saline can improve the image quality of 3D CE - MRA.
出处 《实用临床医药杂志》 CAS 2012年第23期54-56,共3页 Journal of Clinical Medicine in Practice
基金 中国高校医学期刊临床专项资金(11220227)
关键词 磁共振血管成像 三维 颈动脉 规范化 magnetic resonance angiography three dimensional carotid artery standardization
  • 相关文献

参考文献7

二级参考文献35

  • 1韩鸿宾,沙琳,刘洪东,张树墩,刘溢,边杰,董志.MR快速多时相造影增强与时间飞跃血管成像在颈部血管疾病中诊断价值的对比研究[J].中华放射学杂志,2004,38(7):737-741. 被引量:17
  • 2Prince MR, Narasimham DL, stanley JC, et al. Breath-hold gadolinium-enhanced MR angiography of the abdominal arota and its major branches. Radiology, 1995,197:785-792.
  • 3Dake MD,Kato N,Mitchell RS,et al.Endovascular stent-graft placement for the treatment of acute aortic dissection.N Engl J Med,1999,340:1546-1552.
  • 4Khan IA,Nair CK.Clinical,diagnostic,and management perspectives of aortic dissection (Review).Chest,2002,122:313-328.
  • 5Kang SG,Lee DY,Maeda M,et al.Aortic dissection:percutaneous management with a separating stent-graft-preliminary results.Radiology,2001,220:533-539.
  • 6Prince MR,Narasimham DL,Jacoby WT,et al.Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta.AJR,1996,166:1387-1397.
  • 7Krinsky GA,Rofsky NM,DeCorato DR,et al.Thoracic aorta:comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging.Radiology,1997,202:183-193.
  • 8Williams DM,Lee DY,Hamilton BH,et al.The dissected aorta:Ⅲ.Anatomy and radiologic diagnosis of branch vessel compromise.Radiology,1997,203:37-44.
  • 9Cigarroa JE,Isselbacher EM,DeSanctis RW,et al.Diagnostic imaging in the evaluation of suspected aortic dissection:old standards and new directions.N Engl J Med,1993,328:35-43.
  • 10Zeman RK,Berman PM,silverman PM,et al.Diagnosis of aortic dissection:value of helical CT with multiplanar reformation and three-dimensional rendering.AJR,1995,164:1375-1380.

共引文献48

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部