摘要 某液体罐箱的奥氏体不锈钢加热管在使用过程中发生泄漏,经补焊修复后泄漏仍时有发生,对存在泄漏问题的加热管进行宏观及微观断口分析、化学分析、拉伸试验、金相分析以及腐蚀产物的能谱分析等多方面试验,找出了泄漏的原因是由于加热管存在贯穿钢管壁厚的应力腐蚀裂纹所致,并提出了防护的措施。 The austenitic stainless steel heating tube of a liquid tank leaked in the course of being used. The leakage still occurs after welding repair. By means of the macroscopical and microcosmic fracture analysis, chemical analysis, tensile test, metallographic analysis and corrosion produet of energy spectrum analysis and other aspects of the analysis test, the cause of the heating pipe leakage is due to the presence of stress corrosion cracks which passed through the wall thickness. Some prevention measures are put forward in order to avoid the similar accident.
作者 陈文婕
出处 《电焊机》 北大核心 2012年第12期77-81,共5页 Electric Welding Machine
关键词 不锈钢加热管 应力腐蚀裂纹 氯离子 泄漏 stainless steel heating pipe stress corrosion crack chloride ion leakage
  • 相关文献

参考文献4

  • 1Cottis R A.Stress Corrosion cracking[D].NPL,2002.
  • 2Kadry S.Corrosion analysis of stainless steel[J].European Journal of Scientific Reseach, 2008,22(4): 508-5 ! 6.
  • 3王笑天.金属材料学[M].北京:机械工业出版社,1986..
  • 4李凤阳,张亚明,夏邦杰,董爱华,史洪微.热力管网波纹管开裂原因分析[J].腐蚀科学与防护技术,2007,19(4):304-306. 被引量:6

二级参考文献4