期刊文献+

SAE1018盘条闪光对焊后接头脆断原因分析 被引量:2

Analysis on Causes Leading to Brittle Failure at Joints of SAE1018 Wire Rod after Flash Butt Welding
下载PDF
导出
摘要 对SAE1018热轧盘条连续闪光对焊后接头出现的脆断现象进行了分析。结果表明,焊接头脆断是热影响区过热引起的。采取降低焊接二次电压、高温区快冷、降低钢中S含量等措施,可使SAE1018盘条闪光对焊焊接接头过热倾向明显改善。 Analysis on the causes leading to brittle failure at joints of the SAE1018 hot-rolled wire rod after continuous flash butt welding is carried out.The results show that the brittle failure is caused by overheating at the heat affected zone.The tendency of overheating occurred at welded joints of the SAE 1018 wire rod after flash butt welding is obviously improved by adopting such measures as lowering the secondary voltage for welding,rapidly cooling at high temperature zone and lowering the content of sulphur in the steel.
出处 《鞍钢技术》 CAS 2012年第6期51-54,共4页 Angang Technology
关键词 SAE1018盘条 闪光对焊 过热 接头脆断 SAE1018 wire rod flashing butt welding overheating brittle failure at joint
  • 相关文献

参考文献3

  • 1中国机械工程学会.焊接,焊件手册,第一卷,焊件方法及设备[M].北京:机械工业出版社,2008.
  • 2余永宁.金属学原理[M].北京:冶金工业出版社,2005.459-460.
  • 3雍崎龙.钢铁材料中的第二相[M].北京:冶金工业出版社,2006.