期刊文献+

Development of a Poly(vinyl chloride)-based Nitrate Ion-selective Electrode

Development of a Poly(vinyl chloride)-based Nitrate Ion-selective Electrode
下载PDF
导出
摘要 The authors developed a nitrate ion-selective electrode(ISE) based on poly(vinyl chloride)(PVC) membrane with methyltrioctylammonium nitrate as a carrier and 1-decanol as a plasticizer.The performance of the nitrate-sensitive membranes was optimized by tuning the composition of components.The electrode exhibits a linear response with a Nernstian slope of(52±1.0) mV per decade for the nitrate ion concentration ranging from 5.8×10-5 mol/L to 1.0 mol/L.The electrode can be used to detect a low concentration of nitrate ions down to 3×10-5 mol/L in a pH range of 2.1―11.5 without any compensation.The advantage of the electrode includes simple preparation,short response time and good repeatability.The detection performance of the novel electrode on nitrate ions has been tested for water samples. The authors developed a nitrate ion-selective electrode(ISE) based on poly(vinyl chloride)(PVC) membrane with methyltrioctylammonium nitrate as a carrier and 1-decanol as a plasticizer.The performance of the nitrate-sensitive membranes was optimized by tuning the composition of components.The electrode exhibits a linear response with a Nernstian slope of(52±1.0) mV per decade for the nitrate ion concentration ranging from 5.8×10-5 mol/L to 1.0 mol/L.The electrode can be used to detect a low concentration of nitrate ions down to 3×10-5 mol/L in a pH range of 2.1―11.5 without any compensation.The advantage of the electrode includes simple preparation,short response time and good repeatability.The detection performance of the novel electrode on nitrate ions has been tested for water samples.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第6期957-962,共6页 高等学校化学研究(英文版)
基金 Supported by the Project of Wuxi Pollution Prevention Funding Agency,China(No.2008-1)
关键词 Poly(vinyl chloride)(PVC) Methyltrioctylammonium nitrate Nitrate-selective electrode Potentiometric sensor Poly(vinyl chloride)(PVC) Methyltrioctylammonium nitrate Nitrate-selective electrode Potentiometric sensor
  • 相关文献

参考文献31

  • 1Yunus M. A. M., Mukhopadhyay S. C., IEEESens. J., 2011, 11(6), 1440.
  • 2Davis J., Wilkins S. J., Compton R. G., Cardosi M. F., Moorcroft M. J., Electroanalysis, 2000, 12(17), 1363.
  • 3Radojevic M., Bashkin V. N., Practical Environmental Analysis, Royal Society of Chemistry Cambridge Press, Manchester, 2006.
  • 4Zhang J. Z., Fischer C. J., Mar. Chem., 2006, 99(1), 220.
  • 5Merino L., FoodAnal. Methods, 2009, 2(3), 212.
  • 6Ellis P. S., Shabani A. M. H., Gentle B. S., McKelvie I. D., Talanta, 2011, 84(1), 98.
  • 7Katia F., Vaiata Y., Bruno C., Veronique G., Daniele T., Maurice C., Electrochem. Commun., 2010, 12(10), 1439.
  • 8Suzuki O., Watanabe K., Okamoto N., Nozawa H., Ishii A., J. Liq. Chromatogr. Related. Technol., 2005, 28(19), 3077.
  • 9Raessle M., Hilke I., Microchim. Acta, 2006, 154(1), 27.
  • 10Hegedus O., Hegedusova A., Jakabova S., Vargova A., Pemyeszi T., Boros B., Chromatographia, 2010, 71(1), 93.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部