摘要
采用多元统计分析方法并结合在实际检测工作得到的检测结果建立数学模型,对爆炸性气体危险场所电气安全检测所得到的不符合项产生的主要原因进行分析。计算结果显示不符合项是由两个主要成分导致的,一个是项目中与人参与导致的有关因素,另一个是外界有关因素。
A multivariate statistical analysis method is adopeted in analysing main causes of non - conformance from electrcal safe inspection for electrical equipments used in hazardous areas, with a mathematical model set up by results in actual inspection. The results shows that the faults are divided into two main parts, one is related to persons involved in this work, another is of factor from outside.
出处
《电气防爆》
2012年第4期41-43,共3页
Electric Explosion Protection
关键词
多元统计分析法
电气安全检测
原因分析
multivariate statistical analysis method
electrical safe inspection
analysis of causes