期刊文献+

电厂原水氯离子的变化规律

Study on the Rule of Cl^- Change in Power Plant Raw Water
下载PDF
导出
摘要 氯离子浓度是凝汽器不锈钢管选材的重要依据.对不同地区特别是长江口水域氯离子浓度的数据进行了统计分析和影响因素研究.结果表明:长江口水域氯离子浓度近似服从对数正态分布,氯离子浓度与电导率高度正相关,可用电导率推算氯离子浓度及其变化规律. Cl- concentration is an important parameter of material selection for condensers. The Cl- concentration data from various areas especially in the Yangtze River Estuary is analyzed sta- tistically and its influeneial factors are studied. The Cl- concentration in the Yangtze River Estuary has a lognormal distribution approximately. The Cl- concentration highly correlates with conduct- ance, and it, like its change rule, can be calculated with the conductance.
出处 《上海电力学院学报》 CAS 2012年第6期545-548,552,共5页 Journal of Shanghai University of Electric Power
基金 上海市科学技术委员会项目(11DZ2210500 12DZ2280300)
关键词 电厂原水 氯离子浓度 统计分析 凝汽器 power plant raw water Cl- concentration statistical analysis condenser
  • 相关文献

参考文献5

二级参考文献12

  • 1梁磊,周国定,倪鹏,张登云,孙志林,孙军,王义好.铜陵电厂凝汽器黄铜管换不锈钢管[J].汽轮机技术,2004,46(4):305-307. 被引量:7
  • 2梁磊,倪鹏,张登云,孙军,王义好,周国定.铜陵电厂凝汽器不锈钢管选材研究[J].电力技术(北京),2004,37(12):53-55. 被引量:3
  • 3MANSFELD F, LIU G,XIAO H, et al. The corrosion behavior of copper alloys, stainless steels and titanium in seawater[J].Corrosion Science, 1994,36(12) :2063-2095.
  • 4杨武.金属的局部腐蚀[M].北京:化学工业出版社,1993.316.
  • 5杨武 顾溶祥 黎樵粲 等.金属的局部腐蚀[M].北京:化学工业出版社,1995.44-46.
  • 6化工设计全书编辑委员会.换热器设计[J].上海:上海科学技术出版社,1984.
  • 7张万峰译.凝汽器和其它热交换器管的VGB准则[J].电力设计水处理技术,1991,(2).
  • 8GEMoller.Seminarproceedings:PreventionofCondensersFailures—theStateoftheArt[R].EPRI-CS-4329-SR.Dec.1985.section7.
  • 9BechtelNationalInc.Steam-plantSurface-condenserLeakage—studyUpdate[R].EPRI-NP-2062,Finalreport,May1982.
  • 10梁磊,吴一平,周国定.电厂凝汽器冷却管腐蚀及泄漏情况的调查[J].电站辅机,1998(3):6-10. 被引量:5