摘要
通过对3#LF炉的设备用水量大原因进行分析,重点从设备安全,改造成本,改造后操作方便等方面考虑。通过炉盖进水管的改造,以及与能源中心水处理协调,降低3#LF炉设备净环水的供水量,以达到降低水耗的目的。
By analyzing the reason why the amount of water consumption increasing in #3 ladle furnace from several as- pects such as equipment security, transformation cost and easy operation, water consumption can be reduced via trans- formation of the inlet water pipes, reducing water supply quantity of clean circulating water.
出处
《南钢科技与管理》
2012年第4期43-44,39,共3页
NISCO Technology and Management
关键词
LF炉
水冷炉盖
进水管
水耗
ladle furnace
water-cooled cover
inlet water pipe
water consumption