通过对室外消火栓的类型、布置、安装几方面的阐述,提出了在实际设计中应注意的问题,探讨了规范中需要遵守的各项规定,以使消火栓设计更加合理,在火灾中发挥应有的作用。
Through the elaboration to the types,layout,installation several aspects of outdoor fire hydrant,this paper put forward some problems needing attention in actual design,discussed some regulation needed to comply with,in order to make the fire hydrant design more reasonable,play its due role in fire.
出处
《山西建筑》
2013年第2期124-125,共2页
Shanxi Architecture
关键词
室外消火栓
地上式
地下式
高压
低压
outdoor fire hydrant
ground type
underground type
high pressure
low pressure