摘要 针对不同正压送风口大小对高层建筑前室烟气控制效果的影响进行了分析,应用Fire Dynamic Simulation(FDS)场模拟软件对二道门关闭和半开状态下的不同的功率火灾进行模拟研究,研究结果表明,前室二道门半开情况下,在同一送风量下减小送风口截面积有利于提高正压送风防烟效果,随着火源功率的增加,送风口截面积的改变对烟气温度影响效果有限。 This paper analyzed the effect influence of different positive pressure air chamber sizes to high-rise building pre-chamber flue gas control.Application of FDS simulation software made simulation research on different power fire under two door closes and half open state,the results showed that,under pre-chamber two door half open circumstances,reducing air outlet section was beneficial to improve positive pressure air supply and smoke control effect in same air flow.With the increase of fire power,the influence was limited of air outlet section change to smoke temperature impact.
作者 王军
出处 《山西建筑》 2013年第2期136-138,共3页 Shanxi Architecture
关键词 高层建筑 正压送风 风口大小 数值模拟 high-rise building positive pressure air supply air inlet size numerical simulation
  • 相关文献

参考文献4

二级参考文献15

  • 1Marshall N R.Air entrainment into smoke and hot gases in open shafts[J].Fire Research Station,Borehamwood,1986,10:37-46.
  • 2Yang Lizhong,Feng Wengxing,Ye Junqi.Expefimental research on the spatial distribution of toxic gases in the transport of fire smoke[J].Journal of Fire Science,2008,26(1):45-62.
  • 3Feng Wenxing,Yang Lizhong,Fang Tingyong.Movement and species variation of fire smoke in an underground corridor[M].Beijing:Science Press,2006:882-888.
  • 4Qin T X,Guo Y C,Chan C K.Numerieal simulation of fire-induced flow through a stairwell[J].Building and Environment,2005,40(2):183-194.
  • 5Yang Lizhong,Feng Wenxing,Fang Tingyong.Mathematic analysis on smoke concentration of simulated building fire[J].Journal of Applied Fire Science,2005,13(3):181-189.
  • 6Andersson B,Markert F,Holmstedt G.Combustion products generated by hetero-organic fuels on four different fir e test scales[J].Fire Safety Journal,2005,40 (5):439-465.
  • 7Liisa M,Siikonen,Hakonen H.Efficient evacuation methods in tall buildings[J].Elevater World,2003,27(7):78-83.
  • 8Sekizawa A.Study on feasibility of evacuation by elevators in a high-rise building is use of elevator in evacuation really effective for general people[J].Copyright by ASME International,2003,15 (8):118-123.
  • 9卢平,李改.高层建筑火灾烟气流动规律及烟气控制研究[D].合肥:安徽建筑工程学院,2010.
  • 10李元洲,许兆宇.不同开口形式楼梯井内烟气温度及速度分布规律研究[D].合肥:中国科学技术大学,2010.