摘要 分析说明定速汽轮机调节级的临界压比是只与其结构尺寸有关的常数;对级的变工况计算公式进行改进,建立了调节级蒸汽流量变工况的计算模型,结合现场实测参数,实现了调节级临界压比的计算。分别通过一台300MW与一台600MW汽轮机的计算实例,说明该方法的准确性与有效性。 Analysis shows that the critical pressure ratio is a constant only related to its structure size for the governing stage of the constant speed turbine. In this paper, the off-design condition formula for steam turbine is improved, and a steam flow computational model is established for the governing stage combined with test parameters, the critical pressure ratio calculation is obtained. A 300MW and a 600MW steam turbine calculation examples indicate the accuracy and validity of the method.
出处 《汽轮机技术》 北大核心 2012年第6期419-421,433,共4页 Turbine Technology
基金 国家电网浙江省电力公司科技项目资助(ZDK026-20121201)
关键词 汽轮机 临界压比 调节级 弗留格尔公式 流量特性试验 steam turbine critical pressure ration governing stage Flugel formula flow characteristics test
  • 相关文献

参考文献9

二级参考文献28

  • 1唐培全,李慎斌,林兆乐.DEH阀门流量特性试验[J].山东电力高等专科学校学报,2004,7(4):164-167. 被引量:7
  • 2李勇,金国华,曹祖庆.弗留格尔公式的证明及应用[J].汽轮机技术,1995,37(3):158-162. 被引量:26
  • 3谢健育,潘勇坚,赖加良.700 MW机组汽轮机阀门管理设计分析[J].广东电力,2006,19(8):67-70. 被引量:5
  • 4翦天聪.汽轮机原理[M].水利电力出版社,1990..
  • 5王瑞.日本超临界压力汽轮机的运行[A].中国发电设备行业协会汽轮机分会编.超临界压力汽轮机文集[C].,1997,2..
  • 6崔永强.N600型汽轮机高压联合进汽阀模型实验报告[R].,1999.9..
  • 7Joh I , Corer IV ,John K, Reinker, William J. Sumner,Advanees in Steam Path Teehnology [J]. GER-3713D,1996.
  • 8Bourcier P, Bolton J. Progress by Research and Development--Some Recent Examples[J]. Symposium on Steam Turbines and Generators, Monaco, Oct. 12-14,1994.
  • 9潘文全.工程流体力学[M].北京:清华大学出版社,1987..
  • 10剪天聪.汽轮机原理[M].北京:水利电力出版社,1990..

共引文献174

同被引文献60

引证文献7

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部