期刊文献+

双源CT降低时间分辨率对灌注图像影响的研究 被引量:3

Effect of Reducing Temporal Resolution on Image Quality of CT Perfusion by Dual Source CT
下载PDF
导出
摘要 目的:基于最大斜率法数学模型,探讨降低时间分辨率对灌注图像质量及参数的影响。方法:对36例具有脑缺血症状患者的CT灌注成像资料进行回顾性分析。分别选择1帧/1.5S和1帧/3s时间分辨率进行图像处理,对两组图像质量进行主观视觉评价,然后对同一病例选取相同的感兴趣区域进行灌注参数测量,并进行统计学分析。结果:①降低时间分辨率对灌注图像的视觉评分有一定影响,但不影响病灶检出。②各灌注参数绝对值随时间分辨率的降低变化有统计学意义(p<0.05),而参数相对值差异无统计学意义(P>0.05)。结论:在一定范围内降低时间分辨率不影响缺血病灶的检出,可以满足临床需要;但若对灌注参数值进行研究,建议使用较高时间分辨率。 Purpose: Based on the mathematical model of maximum slope, to study the effect of reducing temporal resolution of dual source CT on the image quality and parameter of CT perfusion. Methods: The CT perfusion results of 36 cerebral ischemic cases were analyzed retrospectively. Two temporal resolutions: (1 frame/1.5s and 1 frame/3.0s) were used for the CT perfusion imaging. The image data were processed by VPCT software. Subjective visual evaluation was used to assess the image quality. In addition, the same location of the ROI for measurement of perfusion parameters were recorded and then the variabilities of the parameters were statistically analyzed. Results: (1)The visual scores of image quality ofperfusion parameter maps were lowered when the temporal resolution was reduced, while the detection of lesion was not influenced. (2)Significance difference occurred in the perfusion parameters following by temporal resolution reducing (P〈0.05). However, no significant in relative values (P〉0.05). Conclusion: Reducing of temporal resolution in a certain range will not affect the detection of ischemic lesions and will be benefit for clinical study. However, it is recommended to use a higher temporal resolution to study the perfusion parameters.
出处 《中国医学计算机成像杂志》 CSCD 北大核心 2012年第6期553-556,共4页 Chinese Computed Medical Imaging
关键词 时间分辨率 灌注 辐射剂量 体层摄影术 X线计算机 Temporal resolution Perfusion Radiation dose Tomography, X-ray computed
  • 相关文献

参考文献15

  • 1马春,余聪,赵建农,郭大静,李杰,罗银灯,谢维波,沈霞.CT灌注成像对脑梗死缺血半暗带的动态观察[J].中国医学计算机成像杂志,2008,14(3):195-199. 被引量:10
  • 2Lovblad KO, Baird AE. Computed tomography in acute ischemic stroke. Neuroradiology, 2010, 52:175-187.
  • 3张放,姚振威,冯晓源,孙华平.急性兔脑微栓塞模型的CT灌注成像研究[J].中国医学计算机成像杂志,2011,17(6):540-544. 被引量:1
  • 4陈唯唯,漆剑频,肖明,宋金梅.降低时间分辨力对CT灌注图像的影响[J].放射学实践,2005,20(2):114-117. 被引量:4
  • 5王菁,刘斌,王万勤,吴兴旺.降低时间分辨率对急性脑缺血疾病CT灌注参数值的影响[J].临床放射学杂志,2012,31(3):339-343. 被引量:7
  • 6Wintermark M, Smith WS, Ko NU, et al. Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. AJNR, 2004, 25:720-729.
  • 7Wiesmann M, Berg S, Bohner G, et al. Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time. Eur Radiol, 2008, 18:2967-2974.
  • 8Kloska SP, Fischer T, Sauerland C, et al. Increasing sampling interval in cerebral perfusion CT: limitation for the maximum slope model. Acad Radiol, 2010, 17:61-66.
  • 9Abels B, Klotz E, Tomandl BF, et al. CT perfusion in acute ischemic stroke: a comparison of 2-second and 1-second temporal resolution. AJNR, 2011, 32:1632-1639.
  • 10Miles KA, Hayball M, Dixon AK, et al. Colour perfusion imaging: a new application of computed tomography. Lancet, 1991, 337:643-645.

二级参考文献47

  • 1冀瑞俊,贾建平,卢洁.关于急性缺血性卒中发病时间与缺血半暗带相关关系模式的思考[J].脑与神经疾病杂志,2006,14(5):335-338. 被引量:11
  • 2具海月,高思佳,徐克,王强.脑动脉和静脉增强曲线最高值及增强峰值对CT灌注参数及其信噪比的影响[J].中华放射学杂志,2007,41(7):687-691. 被引量:4
  • 3刘静红,高思佳,石强,付强.不同输入参考动脉对CT灌注图像参数的影响研究[J].中国临床医学影像杂志,2007,18(8):579-581. 被引量:8
  • 4Nakashima T,Minematsu K.Prospects of thrombolytic therapy for acute ischemic stroke.Brain Nerve,2009,61:1003- 1012.
  • 5Altaf N,Auer DP,Gladman J,et al.Microembolization during carotid endarterectomy and diffusion weighted imaging.Stroke, 2005,36:1110- 1111;author reply 1111- 1112.
  • 6Wang X,Lam WW,Fan YH,et al.Topographic patterns of small subcortical infarcts associated with MCA stenosis:a diffusion -weighted MRI study.J Neuroimaging,2006,16:266-271.
  • 7Kurita N,Kawaguchi M,Kakimoto M,et al.Reevaluation of gray and white matter injury after spinal cord ischemia in rabbits. Anesthesiology,2006,105:305-312.
  • 8Wakayama A,Graf R,Rosner G,et al.Deafferentation versus cortical ischemia in a rabbit model of middle cerebral artery occlusion. Stroke,1989,20:1071-1078.
  • 9Zhang Z,Zhang RL,Jiang Q,et al.A new rat model of thrombotic focal cerebral ischemia.J Cereb Blood Flow Metab,1997, 17:123- 135.
  • 10Atochin DN,Murciano JC,G(u|¨)rsoy - Ozdemir Y,et al.Mouse model of microembolic stroke and reperfusion.Stroke,2004,35: 2177-2182.