期刊文献+

Spectroscopic Measurements of Impurity Spectra on the EAST Tokamak 被引量:1

Spectroscopic Measurements of Impurity Spectra on the EAST Tokamak
下载PDF
导出
摘要 Ultraviolet (UV) and visible impurity spectra (200-750 nm) are commonly used to study plasma and wall interactions in magnetic fusion plasmas. Two optical multi-channel analysis (OMA) systems have been installed for the UV-visible spectrum measurement on EAST. These two OMA systems are both equipped with the Czerny-Turner (C-T) type spectrometer. The upper vacuum vessel and inner divertor baffle can be viewed simultaneously through two optical lenses. The OMA1 system is mainly used for multi-impurity lines radiation measurement. A 280 nm wavelength range can be covered by a 300 mm focal length spectrometer equipped with a 300 grooves/mm grating. The Da/Ha line shapes can be resolved by the OMA2 system. The focal length is 750 mm. The spectral resolution can be up to 0.01 nm using a 1800 grooves/mm grating. The impurity behaviour and hydrogen ratio evolution after boroniztion, lithium coating, and siliconization are compared. Lithium coating has shown beneficial effects on the reduction of edge recycling and low Z impurity (C, O) influx. The impurity expelling effect of the divertor configuration is also briefly discussed through multi-channels observation of OMA1 system. Ultraviolet (UV) and visible impurity spectra (200-750 nm) are commonly used to study plasma and wall interactions in magnetic fusion plasmas. Two optical multi-channel analysis (OMA) systems have been installed for the UV-visible spectrum measurement on EAST. These two OMA systems are both equipped with the Czerny-Turner (C-T) type spectrometer. The upper vacuum vessel and inner divertor baffle can be viewed simultaneously through two optical lenses. The OMA1 system is mainly used for multi-impurity lines radiation measurement. A 280 nm wavelength range can be covered by a 300 mm focal length spectrometer equipped with a 300 grooves/mm grating. The Da/Ha line shapes can be resolved by the OMA2 system. The focal length is 750 mm. The spectral resolution can be up to 0.01 nm using a 1800 grooves/mm grating. The impurity behaviour and hydrogen ratio evolution after boroniztion, lithium coating, and siliconization are compared. Lithium coating has shown beneficial effects on the reduction of edge recycling and low Z impurity (C, O) influx. The impurity expelling effect of the divertor configuration is also briefly discussed through multi-channels observation of OMA1 system.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第12期1048-1053,共6页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China (Nos. 10975155, 10990212, and 11175208) National Magnetic Confinement Fusion Science Program (Nos. 2011GB101004, 2011GB107000, and 2012GB101001) and the Scientific Instrument Development Project of Chinese Academy of Sciences (No. YZ200922)
关键词 OMA optical multi channel analysis BORONIZATION lithium coating wall condition TOKAMAK OMA optical multi channel analysis, boronization, lithium coating, wall condition, tokamak
  • 相关文献

参考文献16

  • 1Behringer K, Summers H P, Denne B, et al. 1989, Plasma Phys. Control. Fusion, 31:2059.
  • 2Putterich T, Dux R, Gafert J, et al. 2003, Plasma Phys. Control. Fusion, 45:1873.
  • 3Isler R C, Colchin R J, Brooks N H, et al. 2001, Physics of Plasmas, 8:4470.
  • 4Huang J, Wan B N, Li J G, et al. 2006, Nucl. Fusion, 46:262.
  • 5Isler R C, Brooks N H, West W P, et al. 2007, Physics of Plasmas, 14:012506.
  • 6Kallenbach A, Dux R, Mayer M, et al. 2009, Nucl. Fusion, 49:045007.
  • 7Huang J, Wan B N, Gong X Z, et al. 2007, Journal of Nuclear Materials, 363:751.
  • 8Gao W, Gao X, Wu Z W, et al. 2008 Plasma Phys. Control. Fusion, 50:115003.
  • 9Colchin R J, Hillis D L, Maingi R, et al. 2003, Rev. Sci. Instrum., 74:2068.
  • 10Wan Y X, Li J G, Weng P D, et al. 2006, Plasma Science and Technology, 8:253.

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部