摘要
以汽油为例,通过对安全静止电导率、电导率理论值、电导率测试值以及灌装时电荷密度的测试值对比分析,对液体静电燃爆危险性与电导率的关系进行了探讨,并提出了预防建议。
Taking the gasoline as example, through the comparable analysis of stationary conductivity, theory value of conductivity, testing value of conductivity and testing value of charge density ,the paper discusses the relation between the risk of electrostatic ignition and conductivity of the liquid and submit preventive suggestions.
出处
《安全、健康和环境》
2012年第12期24-26,共3页
Safety Health & Environment
关键词
静止电导率
液体静电
燃爆危险性
stationary conductivity
liquid electrostatic
risk of ignition