摘要 主要从两个方面讨论了食品包装安全的溶剂残留问题,一方面讲述了食品包装中溶剂残留的危害性;另一方面介绍了顶空直接进样法测定食品包装材料中的溶剂残留,此方法在新标准GB/T 10004-2008溶剂残留限量要求的条件下,运用顶空进样技术,即在达平衡的密闭容器中包材的顶部空间取一定量的气态样品,送入气相色谱进行分析。该方法在含量0.40~20 mg/m2线性关系良好,相关系数在0.999 37~0.999 87之间,加标回收率范围为78.40%~117.77%,相对标准偏差(n=6)为2.87%~6.52%,检出限范围为0.014~0.030mg/m2。该方法简单、快速,能准确的测出食品包装材料中的溶剂残留,有效地控制食品包装材料的质量,减少食品污染。 Two aspects of solvent residues in food packaging safety were discussed mainly. On the one hand, the dangers of residual solvents in food packaging and its reduction measures were involved; On the other hand, describe the headspace direct injection method for the determination of residual solvent in food packaging materials. This method used headspace sampling technology under the new standard GB/T 10004-2008 solvent residue limits of the conditions required, and packaging materials at the top of the space to take a certain amount of gaseous samples in airtight container up to balance, into the gas chromatography analysis. The standard curves were linear in the range of0.4-20 mg/m2 (r=0.999 37 - 0.999 87), the recovery rate between 78.40% and 117.77% with RSD (n=6) in the range of 2.87%-6.52%, the detection limited the range of 0.01-0.030 mg/m2. The method was simple, rapid, and accurate measure of solvent residues in food packaging materials. It effectively controlled the quality of food packaging materials, and reduced the contamination of food.
作者 周丽
出处 《食品工业》 北大核心 2013年第1期184-186,共3页 The Food Industry
关键词 食品包装 溶剂残留 顶空 food package solvent residue headspace
  • 相关文献

参考文献10

二级参考文献70

共引文献194

同被引文献18

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部