期刊文献+

水下集矿作业车运动光学实时跟踪测量系统

Optics based real-time tracking and measuring system for the underwater mining-task-machine trajectory
下载PDF
导出
摘要 集矿作业车是大洋采矿系统的关键技术,在实验定型阶段,高精度的测量集矿作业车的运动学参数是检验集矿作业车的牵引、控制等模块性能必不可少的环节。针对集矿作业车在水中行进、活动范围较大的特点,提出了利用广角镜头进行双目交会测量的光学方法,实现了集矿作业车运动轨迹实时跟踪测量系统。该系统首先在实验室内利用网格板对广角镜头的畸变进行修正;其次,在现场,根据场景中的自然特征,在室内标定的基础上,修正镜头畸变,标定摄像机内外参数;最后,两台摄像机跟踪集矿作业车上的合作特征,实时交会测量获得集矿作业车的运动轨迹,包括位置、速度等。该系统的测量结果与全站仪测量结果的残差为5mm。系统已正式通过验收,并投入使用。 Mining-Task-Machine is the key technology of the Ocean Mining System. To finalize the design, It is the key step to test the traction and control unit of the Mining-Task-Machine by measuring kinematic parameters with high precision. Mining-Task-Machine moves in a large area in water, a binocular measurement method with wide-angle lens is used to make real-time track and measurement of the trajectory of Mining-Task- Machine. Firstly, the lens distortion is calibrated by using gridding board in lab. Secondly, according to the natural feature, the parameters of the lens distortion is modified based on the result in lab and all the camera parameters are calibrated. Finally, the binocular system tracks a cooperative feature on Mining-Task-Machine and measures the motion trajectory including position and velocity, etc. of it on real time. The residual between the result of the system and the total station is about 5 mm. The system has passed the examination and evaluation, and has been put into'use.
出处 《国防科技大学学报》 EI CAS CSCD 北大核心 2012年第6期125-129,共5页 Journal of National University of Defense Technology
基金 国家自然科学基金资助项目(11072263)
关键词 摄像测量 集矿作业车 广角镜头 畸变 videometrics mining-task-machine wide-angle lens distortion
  • 相关文献

参考文献11

  • 1崔木花,董普,左海凤.我国海洋矿产资源的现状浅析[J].海洋开发与管理,2005,22(5):16-21. 被引量:10
  • 2Ganapathy S. Decomposition of transformation matrics for robot vision [J]. Proceedings of IEEE Int Conference Robotics Automat. 1984:130 - 139.
  • 3Zhuang H Q, Shiu Y. A noise-insensitive algorithm for robotic hand/eye calibration with or without sensor orientation measurement[J]. IEEE Trans Sys Man Cybomet, 1993, 23 : 1168 - 1175.
  • 4Zhuang H Q, Roth g S, Wang K C. Robot ealibration by mobile camera system[J]. Journal of Robotic Systems, 1994, 11 (3) : 155 - 168.
  • 5Zhuang H Q, Roth Z S, Wang K C. Error-model-based robot calibration using the modified CPC model [ J ]. Int Journal of Robot Comp Integrated Manufact,1993, 10(4) : 287 -299.
  • 6Zhuang H Q, Wang K C, Roth Z S. Simultaneous calibration of a robot and a hand mounted camera[J]. IEEE Trans on Robotics and Automation, 1995, 11(5) : 649 -660.
  • 7Zhuang H Q, Roth Z S. A note on calibration of wrist-mounted robotic sensor by solving homogeneous transform equations of the form AX = XB [ J ]. IEEE Trans on Robotics and Automation, 1995, 7(3) : 877 -878.
  • 8Tsai B Y. A versatile camera calibration technique for high- accuracy 3D machine vision metrology using off-the shelf TV cameras and lenses [ J ]. IEEE Journal of Robotics and Automation,1987, BA-3(4) : 323-344.
  • 9Weng J Y, Cohen P, Hemiou M. Camera calibration with distortion models and accuracy evaluation [J]. IEEE Trans on PAMI, 1992, 14(10) : 965-980.
  • 10邱志强,陆宏伟,于起峰.用射影不变性纠正鱼眼镜头畸变[J].应用光学,2003,24(5):36-38. 被引量:20

二级参考文献8

共引文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部