摘要 根据AAPM TG43U1推荐的种子源剂量参数计算公式,得到125I-103Pd复合种子源剂量参数计算公式,并且推广到n种放射性核素复合种子源剂量参数计算公式。使用蒙特卡罗方法计算125I-103Pd复合种子源的剂量率常数、径向剂量函数和各向异性函数的数值,对径向剂量函数和各向异性函数进行拟合,得到经验公式。使用单一源125I的参数计算结果和相关数据进行了比较。得到单一源125I的剂量率常数为0.959(cGy.h–1.U–1),与AAPM TG43U1中一种相类似的种子源6711(AH)的推荐值相差0.6093%。 According to dose parameters calculation formula of seed source recommended by AAPM TG43U1, 125I-1~3pd seed source dose parameters calculation formula and a variety of radionuclides composite seed source of dose parameters calculation formula can be obtain. Dose rate constant, radial dose function and anisotropy function of 125I-103pd composite seed source are calculated by Monte-Carlo method, Empiric equations are obtained for radial dose function and anisotropy function by curve fitting. Comparisons with the relative data recommend by AAPM are performed. For the single source, the deviation of dose rate constant is 0.959 (cGy·h-1·U-1), and with 0.6093% from the AAPM.
出处 《核技术》 CAS CSCD 北大核心 2013年第1期20-25,共6页 Nuclear Techniques
关键词 蒙特卡罗方法 剂量学参数 125I-103Pd 经验公式 Monte-Carlo method, Dosimetric characteristics, 125I-103pd, Empiric equation
  • 相关文献

参考文献8

  • 1李忠勇,高惠波,金小海,陈大明.近距离治疗肿瘤的放射性粒子研究进展[J].同位素,2011,24(2):118-123. 被引量:23
  • 2孙亮,李君利.^(125)I短程治疗源剂量计算参数的蒙特卡罗确定[J].原子能科学技术,2006,40(6):657-661. 被引量:6
  • 3Nath R,Anderson LL,Luxton G,et al.Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No.43[].Medical Physics.1995
  • 4HUBBELL J H,SEL TZER S M.Tables of Xray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z=1 to 92 and 48 additional substances of dosimetric interest[].NISTIR.2004
  • 5George Fred,,Max Taghizadeh.Hybrid source containing multi-radionuclides for use in radiation therapy[].US/A.
  • 6Meigooni A L I,Sharifeh A PH D,et al.TG-43parameterization of a novel brachytherapy sourcedesigned with multi-radioisotopes[].Brachytherapy.2008
  • 7Rivard M J,Coutsey B M,Dewerd L A,et al.Update ofAAPM task group No43 report:A revised AAPM protocolfor brachytherapy dose calculations[].Medical Physics.2004
  • 8X-5 Monte Carlo Team.MCNP-A General Monte Carlo N-Particle Transport Code,Version 5,LA-UR-03-1987[]..2003

二级参考文献35

  • 1罗素明,朱卫国.近距离粒子源植入治疗剂量质量控制[J].中国肿瘤,2004,13(8):495-496. 被引量:8
  • 2申文江.放射性粒子植入的现状与进展[J].中国微创外科杂志,2007,7(2):118-119. 被引量:54
  • 3Goldberg SW, London ES. Zur frage der bezie- hungen zwischen becquerel-strahlen und hautaffectionen[J]. Dermatologische Zeitschrift, 1903, 10(5): 457-462.
  • 4Pasteau O, Degrais P. The radium treatment of cancer of the prostate[J]. Arch Roentgen Ray, 1914, 28(4): 396-410.
  • 5Hilaris BS, Whitmore WF, Batata MA, et al. Ra- diation therapy and pelvic node dissection in the management of cancer of the prostate[J]. Ameri- can Journal of Roentgenology, 1974, 121(4): 832- 838.
  • 6Whitmore WF, Hilaris B, Grabstald H. Retro- public implantation of iodine-125 in the treatment of prostate cancer[J]. Journal of Urology, 1972, 108(7): 918-920.
  • 7Holm HH, Juul N, Pedersen JF,et al. Transperi neal 125-iodine seed implantation in prostatic canc er guided by transrectal ultrasonography[J]. Jour nal of Urology, 1983, 130(1):283-286.
  • 8Blasko JC, Radge H, Schumacher D. Transperi- neal percutaneous iodine-125 implantation of pros- tatic carcinoma using transrectal ultrasound and template guidance[J]. Endocuriether Hypertherm Oncol, 1987, 3(1): 131-139.
  • 9John LR, David NC. X-ray-emitting interstitial implants: US, 4702228[P]. 1987-10-27.
  • 10Williamson JF. Brachytheragy technology and ph- ysics practice since 1950: a half-century of pro- gress[J]. Physics in Medicine and Biology, 2006, 51(13) : R303-R325.

共引文献27

同被引文献11

  • 1李文华,张书旭,徐海荣.宫颈癌后装治疗的剂量分布测试[J].中国医学物理学杂志,2005,22(3):501-504. 被引量:3
  • 2李浦,狄小云,余华,杨丽芳.宫颈癌后装治疗中直肠、膀胱剂量的研究[J].中国医学物理学杂志,2007,24(4):243-244. 被引量:4
  • 3中华人民共和国卫生行业标准.WS262-2006,后装γ源治疗的患者防护与质量控制检测规范[S].北京:人民卫生出版社,2007.
  • 4中华人民共和国国家职业卫生标准.GBZ121-2002,后装γ源近距离治疗卫生防护标准[S].北京:人民卫生出版社,2002.
  • 5Borca V C, Pasquino M, Russo G, et al. Dosimetric characterization and use of Gafchromic EBT3 film for IMRT dose verification[J]. Journal of Applied Clinical Medical Physics, 2013, 14(2): 158-171.
  • 6Rao M. Application of mathematical morphology to biomedical image processing[J]. University of Westminster, 2004, 3(5): 564-567.
  • 7FeHner C, Putter R, Knocke T H, et al. Comparison of radiography and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects[J]. Radiotherapy and Oncology, 2001, 58(1): 53-56.
  • 8Das R K, Patel R, Shah H, et al. 3D CT-based high-dose-rate breast brachytherapy implants: treatment planning and quality assurance[J]. International Journal of Radiation Oncology Biology Physics, 2004, 59(4): 1224-1228.
  • 9余耘,冯宁远.微型铱源空间角分布的测定[J].中华放射肿瘤学杂志,1993,2(1):62-63. 被引量:7
  • 10卢峰,陈睿,尚云英,陈跃,闵楠,陈英民,邓大平.免冲洗胶片法测量后装机^192Ir放射源到位精度及步进距离精度[J].中华放射医学与防护杂志,2014,34(7):543-546. 被引量:5