期刊文献+

CO_2双缸滚动活塞膨胀机模拟及实验研究 被引量:2

The Experiment Research and Simulation of the CO_2 Two-Cylinder Rolling Piston Expander
原文传递
导出
摘要 本文对CO_2双缸滚动活塞式膨胀机的膨胀过程进行了模拟,分析了不同长度直径的中间通道对膨胀机膨胀过程的影响,综合考虑各种因素,得出了中间通道取长度为20 mm直径为4 mm时为最佳,依据模拟结果对CO_2双缸滚动活塞式膨胀机进行了改造,并利用CO_2跨临界循环水-水热泵系统进行了性能测试,并得出了初步的测试结果,测试结果表明,改造后的带膨胀机热泵系统运行状况已经由原来的偏离正常状态进入了比较正常的运行状态,膨胀机的膨胀比较之改造前也有所提高。测试结果显示膨胀机的等熵效率最高达到了42.3%。 The expansion process of the expander is simulated in this paper.The influence of intermediate channel with different diameter and length is analyzed.And The length 20 mm as well as the diameter 4 mm of the intermediate channel proves optimum.The prototype is reconstructed based on the simulation result and tested on the water-water heat pump system.The test result indicates that the operation condition is improved and the expansion ratio is increased.And the efficiency of the expander is up to 42.3%.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2013年第1期36-39,共4页 Journal of Engineering Thermophysics
基金 国家自然科学基金资助项目(No.50976075 No.51076111)
关键词 CO_2 双缸滚动活塞式膨胀机 模拟 CO_2 two-cylinder rolling expander simulation
  • 相关文献

参考文献3

二级参考文献16

  • 1Lorentzen G. Revival of carbon dioxide as a refrigerant [J]. lntJRefrig, 1994, 17 (5) :292-301.
  • 2Halozan H, Rieberer R. Heat pump systems with ammonia as referent [ C]//The 7th IIR Gustav Lorentzen Con- ference on Natural Working Fluids. Trondheim, Norway, 2006.
  • 3Rees B, Rohrer C, Shapiro D, et al. Performance testing and comparison of liquid overfeed and cascade CO2 systems with R404a primary[C]/IThe 22nd Internaional Congress of Refrigeration. Beijing, China, 2007.
  • 4Sienel T, Finckh O. CO2-dx systems for medium- and low-temperature refrigeration in supermarket applications [C]//The 22nd International Congress of Refrigeration. Beijing, China, 2007.
  • 5Cavallini Alberto, Cecchinato Luca, Corradi Marco, et al. Two-stage transcritical carbon dioxide cycle optimisation : A theoretical and experimental analysis [ J ]. Int J Refrig, 2005,28 (8) : 1274-1283.
  • 6Aprea C, de Rossi F, Maiorino A. Experimental results of trans-critical CO2 refrigerator using an air cooling evaporator [ C]//The 7th IIR Gustav Lorentzen Conference on Natural Working Fluids. Trondheim, Norway, 2006.
  • 7Pedro C Simoes, Joao Femandes, Jose Paulo Mota. Dynamic model of a supercritical carbon dioxide heat ex changer [J]. Journal of Supercritical Fluids, 2005,35 167-173.
  • 8Pietro Asinari. Numerical prediction of turbulent convective heat transfer in mini/micro channels for carbon dioxide at supercritical pressure [J] .International Journal of Heat and Mass Transfer, 2005,48 : 3864-3879
  • 9Lorentzen G. The use of natural refrigerants : A complete solution to the CFC/HCFC predicament [J]. Int J Refrig, 1995, 18(3) :190-197.
  • 10Robinson D M,Groll E A. Efficiencies of trans-critical CO2 cycles without an expansion turbine[J]. Int J Refrig, 1998,21 (7) :577-589.

共引文献4