介绍了某四星级酒店项目的供配电设计实例,包括负荷分级、负荷计算、高低压变配电系统、应急发电机组,总结了酒店供配电的设计经验与注意事项,对类似工程设计具有借鉴作用。
Based on the design case of power distribution system in a four-star hotel,including load classification,load calculation,highlow-voltage transformation and distribution system and emergency generating set in hotel,the experience and aspects to be considered for the design of power supply and distribution system were introduced.It could provide references for similar project.
出处
《现代建筑电气》
2012年第12期6-11,19,共7页
Modern Architecture Electric
关键词
配电设计
四星级酒店
高低压配电系统
应急发电机组
power distribution design
four-star hotel
high and low voltage distribution system
emergency generating set