期刊文献+

建筑中水供水系统与消防用水水质改进的技术 被引量:1

Supply of Reclaimed Water System for Building and the Improvement of the Fire Water
下载PDF
导出
摘要 高层民用建筑设置的消防专用高位水池(箱)由于贮水长期停滞不流动,产生污泥,影响灭火效果。笔者建议设置建筑中水供水系统与消防系统合用水池(箱),消防用水得以循环,避免水质恶化,保证消防供水的可靠性。 Because water reservoirs are long stagnant and not flowing,the sludges are produced in the special fire-fighting high pool(tank) of high-rise civil buildings,and they influence extinguishing effect.The author suggests that reclaimed water supply system and the fire-fighting system share a pool(tank),which is useful for the fire-fighting water to cycle,to avoid water quality deterioration,and to guarantee the reliability of the fire-fighting water supply.
出处 《常州大学学报(自然科学版)》 CAS 2012年第4期13-15,共3页 Journal of Changzhou University:Natural Science Edition
关键词 建筑中水 水质污染 合用水池(箱) 水质改进 reclaimed water for building water pollution shared pool(tank) improvement of water quality