摘要
本文通过介绍我国某涉外EPC工程#1机组厂用电率的测试情况,对比了国内工程和涉外工程厂用电率的计算方法,总结了影响厂用电率的因素和应注意的问题,对合同执行过程中厂用电率的控制给出了相应建议,可供涉外工程参考借鉴。
the testing result of auxiliary power consumption of unit #1 of the EPC Engineering is introduced, the power consumption calculating method between domestic and oversea are compared, also the affecting to power consumption and the necessary consideration to power consumption is summed up in this paper, the suggestion for power consumption controlling during project execution is given in the paper, it can be used for reference to the oversea projects
出处
《电力勘测设计》
2012年第6期36-41,共6页
Electric Power Survey & Design
关键词
厂用电率
涉外工程
性能测试
auxiliary power consumption
oversea project
performance testing