摘要 目的观察新生儿经口气管插管导管放置部位(放置一侧口角和放在上唇正中)与保留天数的关系。方法选择在我科行经口气管插管机械通气的新生儿60例为研究对象,分为试验组和对照组。对照组(30例)气管插管导管放置于上唇正中;试验组(30例)导管放置一侧口角。对比两组平均留置天数和脱管率。结果气管插管导管放置一侧口角(试验组)留置天数约为(4.53±1.11)d,明显优于放在上唇正中(对照组)留置天数(2.76±0.98)d,且试验组的总脱管率仅为16.7%,远低于试验组的43.3%,两组差异有统计学意义(P<0.05)。结论新生儿经口气管插管放置一侧口角固定是安全、能可靠固定,减少脱管的一种有效方法。 Objective To observe the reserve days of the catheter at two different placement sites in neonatal orotracheal intubation.Methods Selected 60 cases of newborn with orotracheal intubation treated in our hospital,divided into the test group(30 cases) and control group(30 cases).The control group placed the catheter at the median of upper lip,and the test group placed catheter at angulus oris.Compare the reserve days and number of removal tube of the two groups.Results The reserve day of the test group was about days,better than that of the control group,which was days.The rate of removal tube of the rest group was,lower than that of control group,which was.The differences were statistically significant,P0.05.Conclusions To place catheter in neonatal orotracheal intubation at angulus oris is a safe,reliable fixed,effective method,which is worth popularizing.
出处 《中国医药指南》 2012年第36期402-404,共3页 Guide of China Medicine
关键词 新生儿 经口 气管插管 固定 Neonatal Orotracheal intubation Per os Fix
  • 相关文献

参考文献5

二级参考文献20

  • 1时亚平.不同吸痰时机对气管插管新生儿排痰的影响[J].中国实用护理杂志,2005,21(2):12-14. 被引量:67
  • 2叶枫.体位引流吸痰对气管插管新生儿排痰的效果评价[J].医学理论与实践,2005,18(12):1480-1481. 被引量:7
  • 3刘兆娥,余加林.新生儿机械通气时撤机失败的临床因素[J].中国实用儿科杂志,2006,21(1):69-70. 被引量:19
  • 4黄师菊.儿科护理学术交流暨业务知识讲座[C].1997:132-133.
  • 5Venkataraman ST. Weaning and extabation in infants and children: religion, art, or science [ J ]. Pediatr C fit Care Med,2002,3(2) :203-205.
  • 6Fadeeva GB,Sterkhova GV,Sidorenko SV,et al. Etiology and microbiological diagnosis of nosocomial pneumonia in newborns[ J ]. Antibiot Khimioter,2001,46 (5) : 17-23.
  • 7Walner DL, Loewen MS, Kimura RE. Neonatal sabglottic stenosis-incidence and Trends [ J ]. Laryngoscope ,2001,111 ( 1 ) :48-51.
  • 8Dimitriou G, Greenough A, Endo A, et al. Prediction of extubation failure in preterm infants [ J ]. Arch Dis Child Fetal Neonatal Ed,2002,86( 1 ) : F32-35.
  • 9Kurachek SC, Newth CJ, Quasney MW, et al. Extubation failure in pediatric intensive care : a multiple-center study of risk factors and outcomes [ J ]. Crit Care Med,2003,31 ( 11 ) : 2657-2664.
  • 10Nava S, Ceriana P. Causes of failure of noninvasive mechanical ventilation [ J ]. Respir Care ,2004 ;49 ( 3 ) :295-303.

共引文献39

同被引文献25

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部