食道超声心动图经二尖瓣和升主动脉测定二尖瓣置换术患者心脏指数的一致性 被引量:3

Agreement between cardiac index measured by transesophageal echocardiography through mitral valve and ascending aotra in patients undergoing mitral valve replacement
原文传递
导出
摘要 目的评价食道超声心动图(TEE)经二尖瓣(MV)和升主动脉(AA)测定二尖瓣置换术患者心脏指数(CI)的一致性。方法择期在CPB下行单纯二尖瓣置换术的患者16例,性别不限,年龄18~70岁,体重46~72kg,ASA分级Ⅱ级或Ⅲ级,术前NYHA心功能分级Ⅱ级或Ⅲ级。麻醉诱导及术中维持均采用全凭静脉麻醉。麻醉诱导气管插管后放置TEE探头,于CPB停止后15min(T1)、30min(T2)、60min(T3)时经MV和AA测定CI(CIMV、CIAA)。两种方法的一致性分析采用Bland—AhmanPLOT一致性检验。结果各时点CIMV均低于CIAA(P〈0.01);一致性检验结果:CIMV为1.29—5.52L·min^-1·m^-2,平均(2.6±0.9)L·min^-1·m^-1,CIAA为2.7~8.8L·min^-1·m^-2,平均(4.9±1.7)L·min^-1·m^-2,平均偏差为-2.3L·min^-1·m^-2,95%一致性界限为-5.62~1.03L·min^-1·m^-2,r=-0.577,P〈0.01。结论采用TEE经MV和AA测定的cI具有较好的一致性,但CIAA明显高于CIMV,在临床上该结果的差异较大,两种测定CI的方法不能相互替代。 Objective To determine if the cardiac index (CI) measured by transesophageal echocardio- graphy (TEE) through the mitral valve (MV) agrees with that measured by transesophageal echocardiography through the ascending aorta (AA) .Methods Sixteen ASA Ⅱ orⅢ patients (NYHA Ⅱ or Ⅲ ), aged 18-70 kg, weighing 46-72 kg, undergoing mitral valve replacement under cardiopulmonary bypass (CPB), were studied. Total intravenous anesthesia was used for induction and maintenance of anesthesia. After tracheal intubation, the TEE probe was placed in the esophagus. CI was measured by transesophageal echocardiography through the MV (CIMV) and AA ( CIAA ) at 15, 30 and 60 min after termination of CPB and recorded. All the data were compared by Bland-Ahmau analysis. Results CIMV values were significantly lower at each time point than CIAA values (P 〈 0.01). The results of Bland-Airman comparison: C/My 1.29-5.52 L·min^-1·m^-2, mean was (2.6 ± 0.9) L·min^-1·m^-2, and CIAA 2.7-8.8L·min^-1·m^-2, mean was (4.9 ± 1.7) L·min^-1·m^-2, bias was - 2.3 L·min^-1·m^-2 , and limit of agreement was - 5.62-1.03 L·min^-1·m^-2 resulting in r = - 0.577, P 〈 0.01. Conclusion CI values obtained through the MV agrees well with that measured through the AA using TEE in pa- tients undergoing mitral valve replacement, but CIAA values are significantly higher than CIMv values, there is a large difference between them for clinical use, and both methods for CI measurement cannot replace each other.
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 2012年第11期1376-1378,共3页 Chinese Journal of Anesthesiology
关键词 超声心动描记术 经食管 二尖瓣 主动脉 心排血量 心脏瓣膜假体植入 Echocardiography, transesophageal Mitral valve Aorta, thoracic Cardiac output Heart valve prosthesis implantation
  • 相关文献

参考文献8

  • 1Muhiudeen IA,Kuecherer HF,Lee E. Intraoperative estimation of cardiae output by transesophageal pulsed Doppler echocardiography[J].Anesthesiology,1991,(01):9-14.
  • 2Branthwaite MA,Pradley RD. Measurement of cardiac output by thermal dilution in man[J].Journal of Applied Physiology,1968,(03):434-438.
  • 3Coats AJ. Doppler ultrasonic measurement of cardiac output:reproducibility and validation[J].European Heart Journal,1990,(Suppl 1):49-61.
  • 4Bland JM,Altman DG. Measuring agreement in method comparison studies[J].Statistical Methods in Medical Research,1999,(02):135-160.
  • 5Nishimura RA,Miller FA Jr,Callahan MJ. Doppler echocardiography.theory,instrumentation,technique,and application[J].Mayo Clinic Proceedings,1985,(05):321-343.
  • 6Fellahi JL,Valtier B,Beauchet A. Does positive end-expiratory pressure ventilation improve left ventricular function? A comparative study by transesophageal echocardiography in cardiac and noncardiac patients[J].Chest,1998,(02):556-562.
  • 7Royse CF,Royse AG,Blake DW. Measurement of cardiac output by transesophageal echocardiography:a comparison of two Doppler methods with termodilution[J].Anaesthesia and Intensive Care,1999,(06):586-590.
  • 8Bródka J,Tulecki L,Ciurysek M. Thermodilution vs transesophageal echocardiography for cardiac output measurement in patients with good left ventricle function[J].Anestezjol Intes Ter,2010,(01):15-18.

同被引文献39

  • 1庄心良,曾因明,陈伯銮.现代麻醉学[M].3版.北京:人民卫生出版社,2004:475-487.
  • 2Akiyama K,Arisawa S,Ide M,et al.Intraoperative cardiac assessment with transesophageal echocardiography for de-cision-making in cardiac anesthesia[J].Gen Thorac Car-diovasc Surg,2013,61(6):320-329.
  • 3Perrino AC,Reeves ST.A practical approach to trans-esophageal echocardiography [M].2nd ed.Philadelphia:Lippincott Williams & Wilkins,2008:127-134.
  • 4Podolec P,Tracz W,Hoffman P.Echokardiografia prakty-czna [ M ].Krakow:Medycyna Praktyczna,2005:103-105.
  • 5Balik M,Plasil P,Pazout J,et al.Correlation of cardiac output measurement with transesophageal echocardiogra-phy and bolus termodilution technique in patients with various of tricuspid regurgitation[J].Anest Intenziv Med,2004,15(4):204-208.
  • 6Winter M,Sobkowicz B,Zajac B,et al.Value of intraop-erative transoesophageal echocardiography in monitoring left ventricular function in patients undergoing elective coronary artery bypass grafting [J].Kardiol Pol,2009,67(5):496-503.
  • 7Stockl D,Rodriguez Cabaleiro D,Van Uytfanghe K,et al.Interpreting method comparison studies by use of the bland-ahman plot:reflecting the importance of sample size by incorporating confidence limits and predefined error limits in the graphic [ J ].Clin Chem,2004,50(11):2216-2218.
  • 8Hanneman SK.Design,analysis,and interpretation of method-comparison studies[J].AACN Advanced Critical Care,2008,19(2):223-234.
  • 9Akamatsu S,Kondo Y,Ueda N,et al.Continuous cardiac output measurement with a Doppler-equipped pulmonary artery catheter[J].Anesth Analg,2011,112(4):851-857.
  • 10Moller-Scrensen H,Graeser K,Hansen KL,et al.Measure-ments of cardiac output obtained with transesophageal e-chocardiography and pulmonary artery thermodilution are not interchangeable [J].Acta Anaesthesiol Scand,2014,58(1):80-88.

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部