Seismic Retrofit of Masonry Buildings with Polymer Grid
Seismic Retrofit of Masonry Buildings with Polymer Grid
参考文献15
-
1A. Giuffr6. Letture sulla storiche. Kappa, Roma, Italy. meccanica delle murature 1990. (in Italian).
-
2M. E1Gawady, P. Lestuzzi and M. Badoux, A review of conventional seismic retrofitting techniques for URM, in: The 13th International Brick and Block Masonry Conference, Amsterdam, Netherland, July 2004.
-
3S. Frumento, S. Giovinazzi, S. Lagomarsino and S. Podestb., Seismic retrofitting of unreinforced masonry buildings in Italy, in: NZSEE Conference, Napier, New Zealand, 2006.
-
4Y. Zhuge and S. W. Chuang, Seismic retrofitting of unreinforced masonry buildings -- A literature review, Australian Journal of Structural Engineering 6 (1) (2005) 25-36.
-
5CASCADE Project, Application of reinforcing techniques with polymer grids for masonry buildings, in: Severn R. & Bairrao R. (General Editors), Cooperative Advancements in Seismic and Dynamic Experiments, Report No. 5, 2005.
-
6D. Torrealva, C. Cerr6n and Y. Espinoza, Shear and out o plane bending strength of adobe walls externall reinforced with polypropylene grids, in: The 14th Worlq Conference on Earthquake Engineering, Beijing, China Oct. 2008.
-
7E. Manzoni, A. Dusi and M. Mezzi, Polymeric grid for a cost effective enhancement of the seismic performance of masonry buildings, in: The 14th World Conference on Earthquake Engineering, Beijing, China, Oct. 2008.
-
8M. Mezzi, A. Dusi and E. Manzoni, Polymeric grid for the rehabilitation of masonry structures, in: The 10th International Conference on Inspection, Appraisal, Repairs and Maintenance of Structures, Hong Kong, Oct. 2006.
-
9American Society for Testing Materials E 519-81, Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages, 1981.
-
10A. Colombo, P. Negro and G. Verzelletti, Improving ductility and energy-dissipation capacity of infills by means of polymeric nets, in: The 12th World Conference on Earthquake Engineering, 2000, Auckland, New Zealand.
-
1Seismic Retrofitting Techniques for Existing Masonry Buildings[J].Journal of Civil Engineering and Architecture,2011,5(11):1011-1018.
-
2Evaluation of the Policies for Seismic Retrofit of Buildings[J].Journal of Civil Engineering and Architecture,2012,6(4):391-402.
-
3Giacomo Frulla Giulio Romeo.Structural Aerospace Composite/Metallic Samples under Fatigue Loads: Experimental Activity on Three Case Studies[J].Journal of Mechanics Engineering and Automation,2014,4(4):318-326.
-
4Massimiliano Ferraioli Alberto Maria Avossa.Base Isolation Seismic Retrofit of a Hospital Building in Italy[J].Journal of Civil Engineering and Architecture,2012,6(3):308-321. 被引量:1
-
5米里亚娜·德威塔科维克,吉尔伽那·皮塔斯维斯基,米拉娜·达比克,博杰·米塔维克,宋靖华(译),朱甜(译),李溪喧(校).疯狂的细胞体--元胞自动机在建筑设计中的探索及运用[J].新建筑,2016(5):100-103.
-
6周利剑,范远刚,高斌,单明康,王向英,周利剑,范远刚,高斌,王向英.储液罐子结构振动台试验仿真分析[J].压力容器,2013,30(7):18-23. 被引量:4
-
7Enzo Cartapati.Discussion 2 on "Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake" by G.P.Cimellaro,A.M.Reinhorn and A.De Stefano[J].Earthquake Engineering and Engineering Vibration,2012,11(2):289-290.
-
8Vincenzo Ciampi.Discussion 1 on "Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake" by G.P.Cimellaro,A.M.Reinhorn and A.De Stefano[J].Earthquake Engineering and Engineering Vibration,2012,11(2):281-282.
-
9文永奎,卢文良,杨丽辉.基于研究型教学的土木工程专业大学生创新实验活动探讨[J].高等建筑教育,2009,18(6):122-125. 被引量:7
-
10Gian Paolo Cimellaro,Andrei M. Reinhorn,Alessandro De Stefano.Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake[J].Earthquake Engineering and Engineering Vibration,2011,10(1):153-161.