摘要 目的:麻醉蒸发器是麻醉机的重要部件之一,针对目前的麻醉蒸发器药物输出浓度受各种因素的影响而无法达到高精度平稳给药的问题,设计二级麻醉药物喷射与挥发式蒸发器。方法:利用计算流体力学方法(CFD)及药物的物理特性对蒸发器内部药物流动、浓度场的变化进行三维计算,并对控制合理性进行论证。结果:计算出建立二级麻醉药物喷射与挥发式蒸发器三维模型的相关数据。结论:通过运用流体力学方法对各种数据进行计算,可为二级麻醉药物喷射与挥发式蒸发器的设计提供理论依据。 Objective:Anesthesia evaporator is one of important component of anesthesia machine.The anesthesia evaporator drug concentration of output is affected by various factors.So it is unable to achieve high precision smooth to medicine.In order to solve this problem,we designed two-level anesthetic injection and volatile evaporator.Methods:Using computational fluid dynamics (CFD) method and physical properties of the drug for evaporator internal medicine flow,we evaluated the concentration field changes in three dimensional calculation and to control the rationality of the argument.Results:We calculated secondary anesthetic drug injection and volatile evaporator three dimensional model of the related data.Conclusion:By using the method of fluid dynamics to all sorts of data to carry on the calculation,we can provide a theoretical basis for design of the secondary anesthetic drug injection and volatile evaporator.
出处 《中国医学装备》 2013年第1期22-25,共4页 China Medical Equipment
关键词 麻醉蒸发器 二级麻醉药物喷射 流体力学方法 麻醉机 Anesthesia evaporator Secondary anesthetic drug injection Fluid mechanics method Anesthesia machine
  • 相关文献

参考文献15

  • 1Palayiwa E,Sanderson MH,Hahn CE. Effects of carrier gas composition on the output of six anaesthetic vaporizers[J].British Journal of Anaesthesia,1983,(10):1025-1038.
  • 2Gould DB,Lampert BA,MacKrell TN. Effect of nitrous oxide solubility on vaporizer aberrance[J].Anesthesia and Analgesia,1982,(11):938-940.
  • 3Pashayan AG,Gravenstein JS. Helium retards endotracheal tube fires from carbon dioxide lasers[J].Anesthesiology,1985,(03):274-277.
  • 4Beringer RM,Eltringham RJ. The Glostavent:evolution of an anaesthetic machine for developing countries[J].Anaesthesia and Intensive Care,2008,(03):442-448.
  • 5Tully R,Eltringham R,Walker IA. The portable Glostavent:a new anaesthetic machine for use in difficult situations[J].Anaesthesia and Intensive Care,2010,(06):1085-1089.
  • 6郁红漪.麻醉药-蒸发罐的进展[J].中国医疗器械杂志,2003,27(4):279-280. 被引量:4
  • 7陈华,冯靖.麻醉机技术的最新发展[J].医疗设备信息,2005,20(2):34-35. 被引量:13
  • 8韦汉鹏.麻醉机设计原理及进展[J].医疗设备信息,2005,20(10):44-45. 被引量:13
  • 9杨汝.麻醉蒸发器的原理结构和使用[J].医疗设备信息,2003,18(6):16-18. 被引量:7
  • 10严红剑.有源医疗器械检测技术[M]北京:北京科学技术出版社,20078.

二级参考文献29

共引文献29

同被引文献24

  • 1Hu C,Horstman DJ,Shafer SL.Variability of target-controlled infusion is less than the variability after bolus injection[J]. Anesthesiology, 2005,102(3): 639-645.
  • 2Xu Z,Liu F,Yue Y,et al. C50 for propofol- remifentanil target-controlled infusion and bispectral index at loss of consciousness and response to painful stimulus in Chinese patients:a multicenter clinical trial[J].Anesth Analg, 2009, 108(2).478-483.
  • 3Clouzeau B,Bui HN,Guilhon E,et al.Fiberoptic bronchoscopy under noninvasive ventilation and propofol target-controlled infusion in hypoxemic patients[J]. Intensive Care Med. 2011,37(12): 1969- 1975.
  • 4Chalumeau-Lemoine L,Stoclin A,Billard V,et al.Flexible fiberoptic bronchoscopy and remifentanil target-controlled infusion in ICU:a preliminary study[J].Intensive Care Meal,2013,39(1): 53-58.
  • 5Fanti L, Agostoni M, Arcidiacono PG, et al. Target- controlled infusion during monitored anesthesia care in patients undergoing EUS:propofol alone versus midazolam plus propofol.A prospective double-blind randomised controlled trial[J].Dig Liver Dis, 2007,39(1): 81-86.
  • 6林锐,韩永泉.高质量C程序设计指南[M].2版,北京:电子工业出版社,2003.
  • 7Hausman LM, Eisenkraft JB, Rosenblatt MA. The safety and efficacy of regional anesthesia in an office - based setting[ J]. Journal of Clini- cal Anesthesia, 2008, 20(4) : 271 -275.
  • 8Dorsch JA, Dorsch SE. Anesthesia Machines and Breathing Systems: An Evolutionary Success Story[ M ]//The Wondrous Story of Anesthe- sia. New York, Springer, 2014 : 703 - 714.
  • 9Ballesteros JCR, Martinez JAM, Morhain C, et al. Vaporizer device of multi - fragrance volatile substances: U.S. Patent 8,498,524 [ P ]. 2013 -7 -30.
  • 10Sezdi M, Akan A ,Tank F. Anesthetic gas concentration changes relat- ed to the temperature and humidity in high and low flow anesthesia [ J]. Conf Proc IEEE Eng Med Biol Soc,2009,2009:877 - 880.

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部