摘要 目的评价完全穿刺技术在主动脉夹层腔内隔绝术(endovascular graft exclusion,EVGE)中应用的安全性和有效性。方法回顾性分析我院87例Stanford B型主动脉夹层动脉瘤患者应用EVGE治疗的临床资料,所有患者在局麻或者全麻下经皮股动脉穿刺建立股动脉入路完成EVGE,术后常规使用2套Perclose(Abbott,USA)装置缝合血管。结果使用两套缝合装置成功率97.7%(85/87)。手术时间为(108.0±19.0)min,平均住院时间为(5.3±1.3)d。并发症发生率为2.3%(2/87)。结论完全穿刺技术在EVGE中应用是安全和有效的,手术时间短、住院时间短、并发症低,值得进一步推广和应用。 Objective To evaluate the safety and reliability of total percutaneous technology in endovascular graft exclusion(EVGE)for aortic dissection.Methods The clinical data of 87 patients with Stanford type B aortic dissection aneurysm perfroming EVGE were retrospectively analyzed.All patients completed EVGE under the local anesthesia or general anesthesia via percutaneous femoral artery puncture.After operation,two sets of Perclose device(Abbott,USA)were used to suture the blood vessels.Results The successful rate of suturing was 97.7%(85/87).The operation time was(108.0±19.0)min,and the average hospitalized day was(5.3±1.3)d.The incidence of complication was 2.3%(2/87).Conclusion Total percutaneous technology in endovascular graft exclusion for aortic dissection is safe and effective,with the advantages of shorter operation time,shorter hospitalized day and lower complications.
出处 《山西医科大学学报》 CAS 2013年第1期29-31,共3页 Journal of Shanxi Medical University
基金 重庆市科技攻关计划基金资助项目(CSTC2009AB5196) 军队临床高新技术重点资助项目(2010gxjs071)
关键词 完全穿刺 主动脉夹层 腔内隔绝术 total percutaneous puncture aortic dissection endovascular graft exclusion
  • 相关文献

参考文献6

二级参考文献31

  • 1张斌,许辉,余小平,李晓苏,郭丽君.血管缝合器的临床使用价值[J].中国循环杂志,2004,19(4):273-275. 被引量:7
  • 2[1]Sprouse LR,Botta DM,Hamilton IN.The management of peripheral vascular complications associated with the use of percutaneous suture mediated closure devices[J].J Vasc Surg,2001,33(4):688-693.
  • 3[3]Zorger N,Finkenzeller T,Lenhart M,et al.Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade[J].Eur Radiol,2004,14(4):719-722.
  • 4[4]Nasu K,Tsuchikane E,Sumitsuji S,et al.The safety and efficacy of "pre-closure" utilizing the Closer suture-mediated vascular closure device for achievement of hemostasis in patients following coronary interventions:results of the second Perclose Accelerated Ambulation and Discharge (PARADISE Ⅱ) Trial[J].Invasive Cardiol,2005,17(1):30-33.
  • 5[5]Kornowski R,Brandes S,Teplitsky I,et al.Safety and efficacy of a 6 French perclose arterial suturing device following percutaneous coronary interventions:a pilot evaluation[J].J Invasive Cardiol,2002,14(12):741-745.
  • 6Haas PC,Kracjer Z,Diethrich EB.Closure of large percutaneous access sites using the Prostar XL Percutaneous Vascular Surgery device.J Endovasc Surg,1999,6:168-170.
  • 7Trsul DK,Clair DG,Gray B,et al.Percutaneous endovascular repair of infrarenal abdominal aortic aneurysms:a feasibility study.J Vasc Surg,2000,32:770-776.
  • 8Howell M,Villareal R,Krajcer Z.Percutaneous access and closure of femoral artery access sites associated with endoluminal repair of abdominal aortic aneurysms.J Endovasc Ther,2001,8:68-74.
  • 9Teh LG,Sieunarine K,van Schie G,et al.Use of the percutaneous vascular surgery device for closure of femoral access sites during endovascular aneurysm repair:lessons from our experience.Eur J Vasc Endovasc Surg,2001,22:418-423.
  • 10Rachel ES,Bergamini TM,Kinney EV,et al.Percutaneous endovascular abdominal aortic aneurysm repair.Ann Vaso Surg,2002,16:43-49.

共引文献29

同被引文献15

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部