摘要
本文简述反渗透 (RO)系统在高层建筑中生饮水的开发应用 ,探索了有关的工艺过程和工艺参数及设备选型。根据选用的工艺过程 ,参数以及设备 ,运行和测试结果达到了要求 ,水质符合国家生饮水的标准 ,整套系统能全自动运行。
The development and application of the Reverse Osmosis technique for no-boiling water production are introduced in the paper. The technological process, parameters and the choice of equipment are studied. Through operation and test, the technological process, parameters and equipment selected by the authors meet the requirements of the design. The product water reaches the standards of the national no-boiling water. The system can operate automatically.
出处
《水处理技术》
CAS
CSCD
2000年第4期233-235,共3页
Technology of Water Treatment