通信作业环境空气质量的测定及评价指标相关性 被引量:2

Correlation between Determination of Air Quality and Assessment Indicators in Communication Workshop
下载PDF
导出
摘要 选择计算机终端室、通信机房、通信值班室3个典型作业环境,在设立室外对照点的情况下,现场测定CO;、CO、IP、细菌总数、空气离子、挥发性有机物(VOCS)等10个指标.结果显示:上述指标在机房作业环境内均得以检出,其中VOCS浓度较高。据日均值和id的浓度变化趋势,各指标间存在一定的相关性。特别是空气离子与CO。、CO、VOCS、细菌总数、IP等具有正或负的相关性,可作为评价通信作业环境空气质量的综合指标。 Ten indicators of indoor air quality, such as CO2, CO, IP, bacteria, atmospheric ions and VOCs have been determined in 3 typical indoor communication environments in an office building in Beijing. The results showed that the above indicators were detected positively and the concentrations of typical VOSs as benzene and its homo-logues were at a higher level. There exists the correlation among these indicators, the mean values and the tendency in one day; especially, there are positive or negative correlation between atmospheric ions with inorganic pollutants such as CO2 and CO, organic reductive pollutants such as benzene and its homologues, biological pollutants such as bacteria and physical ones as IP. The concentration of atmospheric ions may be a fine comprehensive index to evaluate the quality of indoor air.
出处 《上海环境科学》 CAS CSSCI CSCD 2000年第8期361-363,共3页 Shanghai Environmental Sciences
关键词 通信作业环境 空气质量评价 相关性 评价指标 Communication workshop Evaluation of air quality Correlation