期刊文献+

聚吡咯修饰电极测定微囊藻毒素 被引量:1

Molecular Imprinted Film Modified Electrode for Detection of Microcystin
下载PDF
导出
摘要 以微囊藻毒素(MC-LR)为模板,采用循环伏安法在金电极的表面电聚合成聚吡咯膜,制备了MC-LR分子印迹电极。在优化制备条件的基础上,对该传感器的线性范围、使用寿命、选择性等进行了研究。结果表明该传感器对MC-LR具有良好的选择性和灵敏度,在0.05~0.30μg/mL浓度范围内呈良好的线性关系,其相对误差为3.2%,加标回收率为91.0%~103%,检出限为0.009 4μg/mL。 A MC-LR molecularly imprinted electrode was prepared by cyclic voltammetry on a gold electrode surface electric polymer into a polypyrrole film in the presence of template molecular,Microcystin(MC-LR).On the basis of the conditions of the optimal preparation,the characteristics of sensor such as linear relationship,service life and selectivity were investigated.Results showed that the sensor exhibited a good selectivity and sensitivity,in the concentration range of 0.05~0.30 μg/mL showed good linear relationship,with the relative error as 3.2%,recovery 91.0%~103% and detection limit of 0.009 4 μg/mL.
出处 《环境科学与技术》 CAS CSCD 北大核心 2013年第1期101-104,110,共5页 Environmental Science & Technology
基金 北京市自然科学基金资助(2102015)
关键词 分子印迹 藻毒素(MC-LR) 吡咯膜 molecular imprinting Microcystin(MC-LR) polypyrrole film
  • 相关文献

参考文献11

  • 1Enefiek S L, Hrudey S E, Peterson H G. Toxin release from Microcystis aeruginosa after chemical treatment [J]. Wat Sci Tech, 1993, 27(3/4) :433-440.
  • 2SivonenK, JonesGToxicCyanobacteriainWate[M]. London: E & FN Spon,1999:41.
  • 3王祥荣,任晶,卢虹虹,樊正球.铜绿微囊藻胞内毒素(Microcystin-LR)提取条件的优化实验[J].复旦学报(自然科学版),2010,49(1):99-103. 被引量:6
  • 4顾志伟,邵国健,余娟,郭和光,任一平.水中微囊藻毒素检测技术进展[J].浙江预防医学,2011,23(3):24-28. 被引量:5
  • 5Cormackp A G, Elorza A 7. Molecularly imprinted polymers: synthesis and characterization[J]. J Chromatography B, 2004, 804( 1 ): 173-182.
  • 6Wang Z, Li H, Chen J,et al. Acetylsalicylic acid electro- chemical sensor based on PATP-AuNPs modified mole- cularly imprinted polymer f'tim[J]. Talanta, 2011, 85(3): 1672-1679.
  • 7Saumya V, Prathish K P, Rao T P. In situ copper oxide modified molecularly imprinted polypyrrole film based voltammetric sensor for selective recognition of tyrosine [J]. Talanta, 2011, 85(2) : 1056-1062.
  • 8Barahona F, Turiel E, Cormack P. Synthesis of core-shell molecularly imprinted polymer microspheres by precipitation polymerization for the inline molecularly imprinted solid- phase extraction of thiabendazole from citrus fruits and orange juice samples[J]. Journal of Separation Science,2011, 34 (2) : 217-224.
  • 9De Barros L A, Martins I, Rath S. A selective molecularly imprinted polymer--solid phase extraction for the determination of fenitrothion in tomatoes[J]. Analytical & Bioanalytical Chemistry, 2010,397(3) : 1355-1361.
  • 10Sambe H, Hoshina K, Hosoya K, et al. Simultaneous deter- mination of bisphenol A and its halogenated derivatives in river water by combination of isotope imprinting and liquid chromatography-mass spectrometry[J]. J Chromatogr A,2006, 1134( 1-2 ) : 16-23.

二级参考文献32

  • 1张昱,杨敏,李宗来,张晶,郭召海.液相色谱-电离质谱法测定微囊藻毒素[J].中国给水排水,2005,21(4):94-96. 被引量:13
  • 2吴和岩,郑力行,苏瑾,施玮.饮用水源水中微囊藻毒素与蓝藻相关性研究[J].环境与职业医学,2005,22(2):130-132. 被引量:8
  • 3李耕.微囊藻毒素-LR的提取与测定[J].环境科学与技术,2005,28(4):46-47. 被引量:8
  • 4雷腊梅,韩博平,宋立荣.时间分辨荧光免疫一步法检测微囊藻毒素的研究[J].环境科学,2007,28(4):872-875. 被引量:4
  • 5Barco M, Lawton L A, Rivera J, et al. Optimization of intracellular mierocystin extraction for their subsequent analysis by high-performance liquid chromatography [J]. J Chromatogr A, 2005,1074: 23-30.
  • 6Lawton L A,Edwards C, Codd G A. Extraction and high performance liquid chromatographic method for the determination of microcystins in raw and treated waters [J]. The Analyst, 1994,119: 1525-1530.
  • 7Sandra P, Diana S A. Recent advances in the sample preparation, liquid chromatography tandem mass spectrometric analysis and environmental fate of microcystins in water [J]. Trends Anal Chern, 2005, 24(7) : 658-670.
  • 8Zhang L F, Ping X F, Yang Z G. Determination of microcystin-LR in surface water using high-performance liquid chromatography/tandem electrospray ionization mass detector [J].Talanta, 2004,62: 193-200.
  • 9Ramanan S, Tang J, Velayudhan A. Solation and preparative purifi cation of microcystin variants [J].J Chromatog A, 2000,883: 103-112.
  • 10Sangolkar L N, Maske S S, Chakrabarti T. Methods for determining mierocystins (peptide hepatotoxins) and microeystin-produeing cyanobaeteria [J]. Water Res, 2006,40: 3485-3496.

共引文献16

同被引文献24

  • 1张丽丽,彭涛,王林,王正平.分子印迹技术在医药化工中的应用[J].化学工程师,2004,18(12):48-50. 被引量:4
  • 2S Dahiya, K Chuttani, R K Khar et al. Metallomics, 2009, 1:409 -417.
  • 3H Yan, W Y Guan, L Shi et al. Food Microbio. , 2010, 144 (2): 310 -316.
  • 4K Prakash, K R Sireesha. Eur. J. Chem., 2012, 9(3): 1077 - 1084.
  • 5J D Smet, K Boussery, K Colpaert et al. J. Chromatogr. B, 2009, 877(10) : 961 -967.
  • 6F Yu, S C Yu, L Yu et al. Food Chem. , 2014, 149:71 -75.
  • 7R H O Montes, M C Marra, M M Rodrigues et al. Eleetroanal. , 2014, 26(2) : 432 -438.
  • 8I-I L Tan, L Zhang, C J Ma et al. ACS Appl. Mater. Inter. , 2013, 5(22): 11791 -11796.
  • 9E C L Cazedey, HR N Salgado. J. Pharm. Anal. , 2013, 3 (5): 382 -386.
  • 10O G Nagel, M C Behran, M P Molina et al. Small Ruminant. Res. , 2012, 102(2) : 26 -31.