期刊文献+

某石化厂合成氨造气洗涤水预热器开裂分析

Cracking Analysis of Washing Water Preheater in Petrochemical Plant
下载PDF
导出
摘要 对某石化厂合成氨造气洗涤水预热器开裂进行失效分析。结果表明,材料热处理工艺不当,致使预热器筒体存在微观组织偏析,引起材料腐蚀性能下降,导致连多硫酸腐蚀开裂。同时针对此种情况提出了切实可行的防止产生类似失效的预防措施。 The failure analysis of washing water preheater was done in a petrochemical plant. The results show that the improper heat treatment of shell body material leads to the presence of microstructure segregation and decreasing corrosion resistance of the shell materials, which results in the corrosion cracking of sulfuric acid. At the same time, prevention measures were put forward to prevent the similar produce failure event.
作者 丁剑鸣
出处 《铸造技术》 CAS 北大核心 2013年第1期51-53,共3页 Foundry Technology
关键词 预热器 热处理 不锈钢 应力腐蚀 preheater heat treatment stainless steel stress corrosion
  • 相关文献

参考文献7

二级参考文献8

  • 1小若正伦[J].metal finishing,1989,87(8):24-26.
  • 2SH/T3096-2001,加工高硫高酸原油重点装置主要设备设计选材导则[S].
  • 3API Publication 581 -2000, Risk Based Inspection Base Resource Document[S].
  • 4API Recommended Practice 580 2002,Risk-Based Inspection [S].
  • 5API RP 571-2003, Demage Mechanisms Affecting Fixed E quipment in the Refining Industry [S].
  • 6中国石油化工设备管理协会.石油化工装置设备腐蚀与防护手册[M].北京:中国石化出版社,2001.p84.
  • 7王非,林英.化工设备用钢[M].北京:化学工业出版社,2003.
  • 8刘双元.不锈钢设备的连多硫酸应力腐蚀开裂与预防[J].石油化工腐蚀与防护,2003,20(4):32-34. 被引量:23

共引文献74

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部