摘要
在岭澳核电站二期循环水泵调试期间,发现其存在超功率现象。综合对比了各种处理方案并结合现场的调试进度,优先选择切割叶轮的方法,解决了工程技术问题。
During commissioning of CW pump of Ling'Ao Ⅱ,over-performance was found;.After comprehensive comparison of various treatment options,combined with field commissioning progress,impeller cutting method was preferably chozen to solve the engineering problems.
出处
《核科学与工程》
CSCD
北大核心
2012年第A01期1-3,共3页
Nuclear Science and Engineering
关键词
岭澳核电站二期
循环水泵
超功率
切割叶轮
Ling'Ao Ⅱ
circulating water pump
over-performance
impeller cutting