介绍了沙铜7号烧结机主抽风机在安装调试中综合保护误动作的现象及特征,分析了故障产生的原因,通过检查接线及电缆并联的方法消除了故障。
Present the phenomenon and characteristics of comprehensive protection misoperation of the main exhaust fan for Sintering Machine 7# in Shagang Group, and analyze the fault reasons, such as the connection fault and cable parallel, etc. and eliminate the faults through the connection check and the cable parallel.