Micromotions and combined damages at the dental implant/bone interface 被引量:7

Micromotions and combined damages at the dental implant/bone interface
下载PDF
导出
摘要 Micromotion and fretting damages at the dental implant/bone interface are neglected for the limitation of check methods, but it is particularly important for the initial success of osseointegration and the life time of dental implant. This review article describes the scientific documentation of micromotion and fretting damages on the dental implant/bone interface. The fretting amplitude is less than 30 l^m in vitroand the damage in the interface is acceptable. While in vivo, the micromotion's effect is the combination of damage in tissue level and the real biological reaction. Micromotion and fretting damages at the dental implant/bone interface are neglected for the limitation of check methods, but it is particularly important for the initial success of osseointegration and the life time of dental implant. This review article describes the scientific documentation of micromotion and fretting damages on the dental implant/bone interface. The fretting amplitude is less than 30 l^m in vitroand the damage in the interface is acceptable. While in vivo, the micromotion's effect is the combination of damage in tissue level and the real biological reaction.
出处 《International Journal of Oral Science》 SCIE CAS CSCD 2012年第4期182-188,共7页 国际口腔科学杂志(英文版)
基金 the support of the National Natural Science Foundation of China (Nos. 81170996, 81070867, and 81100777) Sichuan Province Science and Technology Innovation Team Program (2011JTD0006)
关键词 dental implant fretting damage MICROMOTION dental implant fretting damage micromotion
  • 相关文献

参考文献2

二级参考文献17

  • 1于海洋,蔡振兵,朱旻昊,周仲荣.人股骨密质骨横断面的微动磨损特性研究[J].摩擦学学报,2004,24(5):448-452. 被引量:13
  • 2Waterhouse R B. Fretting Corrosion. Oxford: Pergamon,1972.
  • 3Zhou Z R, Vincent L. Cracking induced by fretting of aluminium alloys. Transactions of the ASME, 1997, 119(36):36~42.
  • 4Goodacre C J, Kan J Y K, Rungcharassaeng K. Clinical complication of osseointegrated implants. J Prosthet Dent,1999, 81:537~552.
  • 5Mchargue C J. Ion implantation in metals and ceramics.International Metal Reviews, 1986, 31: 49~76.
  • 6Roberts B. Proceedings of world tribology congress. London: Mechanical Engineering Publications Limited, 1997.
  • 7Albrektsson T, Branemark P I, Hanson H A, et al. Osseointegrafted titanium implants: requirements for ensuring a long-lasting direct bone-to-implant anchorage in man.ActaOrthopScand, 1981, 52: 155~170.
  • 8Branemark P L. Osseointegration and its experimental background. J. ProsthetDent., 1985, 50:399~410.
  • 9Marco V, Roberto M, Marek B, et al. Large-sliding contact elements accutately predict levels of bone-implant micromotion relevant to osseointegration. Journal of Biomechanics, 2000, 33:1 611~1 618.
  • 10YU Hai-yang, CAI Zhen-bing, ZHOU Zhong-rong, et al. Fretting damage of cortical bone against titanium and its alloy[J]. Wear, 2005, 259(7-12):910-918.