期刊文献+

1000MW机组主厂房单边钢次梁与混凝土框架主梁劲型预埋铁焊接节点研究 被引量:3

Study on embedded steel welding joint of single side steel secondary beam and concrete frame girder for 1000MW unit of main factory building
下载PDF
导出
摘要 通过对主厂房结构方案的空间需求分析,研究常见的主厂房楼层钢次梁与框架主梁节点模型的形式及特点,提出在1 000 MW机组主厂房楼层钢次梁与框架主梁连接采用劲型预埋铁焊接方式,以节省挑耳空间,方便施工,缩短施工周期,减少建设期投资。 Through analysis of space need for the structure scheme of the major factory building, the common types and characteristics of joint model for steel secondary beam and frame girder of the major factory building were studied,it was proposed that adopting the embedded steel welding mode for connection of steel secondary beam and frame girder in 1000MW unit of main factory building can save projecting cave space, facilitate construction, shorten construction period and reduce construction investment.
作者 周柏睿
出处 《工程建设》 2012年第6期51-52,73,76,共4页 Engineering Construction
关键词 单边钢次梁 框架主梁 劲型预埋铁 焊接 single side steel secondary beam frame girder strength type embedded steel welding