POCT技术在临床应用的现状与问题 被引量:11

Clinical application of point of care testing and the potential problems
原文传递
导出
摘要 床旁检验(point of care testing,POCT)技术在临床应用范围日渐广泛,该技术的主要优势是能快速得到检验结果,使临床医生能迅速做出临床决策并采取适当的处置和干预措施。但是,也应该清醒地看到POCT在帮助患者成功得到治疗的同时,存在着导致患者伤害的重大可能。尽早制定出台POCT规范性文件显得尤为必要,只有实施POCT技术准入、实施全面规范的质量管理、加强医师、护士及相关人员培训,方能使POCT技术健康地造福于社会。 The clinical application of POCT technology is growing wider, the most significant advantage of this technology is to get the test results quickly. Therefore clinicians could make clinical decisions in time and choose appropriate approaches or interventions. However, it should be taken seriously that while POCT helps patients to get medical care successfully, the potential harm to the patients cannot be ignored. Hence it is essential that normative documents should be imposed as soon as possible. The technology of POCT can benefit the entire society only if the proper administration to approve the use of POCT technology is taken control of; the comprehensive and normative quality management is implemented, and the appropriate training to the related clinicians and nurses is enforced.
作者 李智
出处 《中华检验医学杂志》 CAS CSCD 北大核心 2012年第12期1062-1065,共4页 Chinese Journal of Laboratory Medicine
关键词 POCT 质量管理 Point-of-care testing Quality management
  • 相关文献

参考文献26

  • 1Price CP,John A,Hicks JM. Point-of-Care Testing[M].Washington,DC:AACC Press,2004.
  • 2NACB. Laboratory Medicine Practice Guidelines:Evidence-Based Practice for POCT[M].Washington,DC:AACC Press,2007.
  • 3U.S.Department of Health and Human Services,Food and Drug Administration,Center for Devices and Radiological Health. Recommendations:Clinical Laboratory Improvement Amendments of 1988 (CLIA) Waiver Applications for Manufacturers of In Vitro DiagnosticDevices[M].2008.
  • 4Cao Q,Mahalanabis M,Chang J. Microfluidic chip for molecular amplification of influenza A RNA in human respiratory specimens[J].PLoS,2012.e331761.
  • 5Zhang GJ,Chai KT,Luo HZ. Multiplexed detection of cardiac biomarkers in serum with nanowire arraysusing readout ASIC[J].Biosensors and Bioelectronics,2012.218-223.
  • 6Yan J,Ge L,Song X. Paper-based electrochemilumincscent 3D immunodevice for lab-on-paper,specific,and sensitive point-of-caretesting[J].Chemistry-A European Journal,2012.4938-4945.
  • 7Buchegger P,Sauer U,Toth-Székély H. Miniaturized protein microarray with intemal calibration as point-of-care device for diagnosis of neonatal sepsis[J].Sensors (Basel),2012.1494-1508.
  • 8Mahieu L,Marien A,De Dooy J. Implementation of a multi-parameter Point-of-Care-blood test analyzer reduces central laboratory testing and need for blood transfusions in very low birth weight infants[J].Clinica Chimica Acta,2012.325-330.
  • 9Ehrmeyer SS,Laessig RH. Point-of-care testing,medical error,and patient safety:a 2007 assessment[J].Clinical Chemistry and Laboratory Medicine,2007.766-773.
  • 10Wu AH,Apple FS,Ciblel WB. National Academy of Clinical Biochemestry Standards of Laboratory Practice:recommendation for the use of cardiac markers in coronary artery diseases[J].Clinical Chemistry,1999.1104-1121.

二级参考文献11

  • 1Price CP.Point of care testing[J].BMJ,2001,322(7297):1285-1288.
  • 2Nichols JH.Quality in point-of-care testing[J].Expert Rev Mol Diagn,2003,3(5):563-572.
  • 3Wu AH,Apple FS,Gibler WB,et al.National academy of clinical biochemistry standards of laboratory practice:recommendations for the use of cardiac markers in coronary artery diseases[J].Clin Chem,1999,45(7):1104-1121.
  • 4Demir M,Kanadasi M,Akpinar O,et al.Cardiac tro-ponin T as a prognostic marker in patients with heart failure:a 3-year outcome study[J].Angiology,2007,58(5):603-609.
  • 5Jaryno S,Bennett K,Loder C,et al.Validation of a new whole blood coagulation monitoring system.J Extra Corpor Technol,2002,34:271-275.
  • 6Hemkens LG,Hilden KM,Hartschen S,et al.A randomized trial comparing INR monitoring devices in patients with anticoagulation self-management:evaluation of a novel error-grid approach.J Thromb Thrombolysis,2008,26:22-30.
  • 7Moore GW,Henley A,Cotton SS,et al.Clinically significant differences between point-of-care analysers and a standard analyser for monitoring the International Normalized Ratio in oral anticoagulant therapy:a multi-instrument evaluation in a hospital outpatient setting.Blood Coagul Fibrinolysis,2007,18:287-292.
  • 8李镒冲,李晓松.两种测量方法定量测量结果的一致性评价[J].现代预防医学,2007,34(17):3263-3266. 被引量:154
  • 9高润霖.急性心肌梗死诊断和治疗指南[J].中华心血管病杂志,2001,29(12):710-725. 被引量:4903
  • 10杨振华,潘柏申,许俊堂.中华医学会检验学会文件心肌损伤标志物的应用准则[J].中华检验医学杂志,2002,25(3):185-189. 被引量:400

共引文献19

同被引文献87

引证文献11

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部