摘要
单层改性沥青防水卷材屋面系统项目设计阶段需要考虑的因素,主要有风压、防火措施、安全措施以及主材、配件与施工机具的优选等;本文重点介绍了屋面系统各构造层次以及细部节点构造的设计与施工,指出该系统用于旧屋面翻新的优势以及国外最新发展趋势。
Wind pressure, fire prevention, safety precautions and the optimization of the principal material, accessories and construction equipments should be taken into consideration in the design of the roof system of single-ply modified asphalt waterproofing membrane. The paper describes hierarchy structure of the roof system as well as the design and construction of the roof details. It also points out that the benefits of the system applied in roof renovation projects and its latest development in foreign countries.
出处
《中国建筑防水》
2013年第3期13-17,20,共6页
China Building Waterproofing
关键词
单层卷材屋面
改性沥青防水卷材
固定件
细部节点
屋面翻新
single-ply membrane roof
modified asphalt waterproofing membrane
fasteners
details
roof renovation