依据泡沫接触式冷却器结构特性 ,采用数学模型方法 ,结合实例 ,提出了工艺设计方法 ,包括冷却器截面积、泡沫层高度、冷却器外加水量及空气流动的压力损失。
According to the specific property of the structure of foam contact type cooler,the technical design method was put forward by means of mathematic model,including the crosssectional area of cooler,the height of foam bed,the makeup water of cooling and the loss in head of the air flowing.A concrete instance was given.This method was available to direct the development design and production operation of foam contact type cooler.