期刊文献+

基于CT-ON-RAIL系统开展的图像引导自适应放疗研究进展 被引量:7

Progress in Image-guided Adaptive Radiotherapy Based on CT-ON-RAIL System
下载PDF
导出
摘要 本文概述了自适应放疗(ART)的发展及其主要临床应用现状,主要论述了基于CT-ON-RAIL系统开展图像引导ART的流程及优势所在,并对ART未来的发展方向进行了展望,为从事ART的研究人员和医务工作者提供参考。 This paper demonstrates the development and clinical application of adaptive radiotherapy(ART), discusses the process and advantages of image-guided ART based on the CT-ON- RAIL system, also analyzes the future development trend of ART, in order to provide a reference for ART researchers and medical workers.
出处 《中国医疗设备》 2013年第1期62-65,85,共5页 China Medical Devices
基金 广西科学研究与技术开发计划课题(2011D39)
关键词 自适应放疗 图像引导放疗 滑轨CT adaptive radiotherapy image-guided radiotherapy CT-ON-RAIL
  • 相关文献

参考文献17

  • 1刘咏梅,李平.图像引导的自适应放疗研究进展[J].中国肿瘤临床,2008,35(22):1314-1316. 被引量:11
  • 2徐寿平,解传滨,鞠忠建,戴相昆,巩汉顺,郭妍妍,王连元.螺旋断层放疗MVCT成像剂量测量及其分析[J].癌症,2009,28(8):886-889. 被引量:13
  • 3尚进,李东.TOMOTHERAPY螺旋断层放射治疗的现状与应用前景[J].中国医疗设备,2012,27(2):48-50. 被引量:14
  • 4殷蔚伯;余子豪;徐国镇.肿瘤放射治疗学[M]北京:中国协和医科大学出版社,2007175-182.
  • 5于金明;殷蔚伯;李宝生.肿瘤精确放射治疗学[M]济南:山东科学技术出版社,200424-25.
  • 6Yan D,Vicini F,Wong J. Adaptive radiation therapy[J].Physics in Medicine and Biology,1997,(01):123-132.
  • 7王鑫.鼻咽癌调强放射治疗实施过程质量保证的研究[D]上海:复旦大学,2000.
  • 8刘亚军,黄华.近十年来放射治疗技术与设备的进展[J].中国医疗设备,2012,27(6):9-10. 被引量:15
  • 9Ekberg L,Holmberg O,Wittgren L. What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer[J].Radiotherapy and Oncology,1996,(01):71-77.
  • 10Martinez AA,Yan D,Lockman D. Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensitymodulated beams for prostate cancer[J].International Journal of Radiation Oncology,Biology,Physics,2001,(05):1226-1234.

二级参考文献66

  • 1吕庆文,陈超敏,周凌宏,李树祥,林世寅.精确放射治疗技术的现状与发展[J].中国医学物理学杂志,2005,22(1):373-375. 被引量:10
  • 2Mackie TR, KapatoesJ, Ruchala K, et al. Image guidance for precise conformal radiotherapy[J]. Int J Radiat Oncol Biol Phys, 2003, 56(1): 89-105.
  • 3van Herk M. Errors and margins in radiotherapy[J]. Semin Radiat Oncol, 2004, 14(1): 52-64.
  • 4Yan D, Lockman D, Brabbins D, et al. An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer[J]. Int J Radiat Oncol Biol Phys, 2000, 48(1):289-302.
  • 5Yan D, Vicini F, Wong J, et al. Adaptive radiation therapy[J]. Phys Med Biol, 1997, 42(1): 123-132.
  • 6Martinez AA, Yan D, Lockrnan D, et al. Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer[J]. IntJ Radiat Oncol Biol Phys, 2001, 50(5): 1226-1234.
  • 7Birkner M, Yah D, Alber M, et al. Adapting inverse planning to patient and organ geometrical variation: algorithm and imple-mentation[J]. Med Phys, 2003, 30(10): 2822-2831.
  • 8Brabbins D, Marfinez A, Yah D, et al. A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: analysis of chronic toxicity[J]. IntJ Radiat Oncol Biol Phys, 2005, 61(2): 400-408.
  • 9Ghilezan M, Yah D, LiangJ, et al. Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvemeiat can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery[J]. Int J Radiat Oncol Biol Phys, 2004, 60(5): 1602-1610.
  • 10Wong JR, Grimm L, Uematsu M, et al. Image-guided radio-therapy for prostate cancer by CT-linear accelerator combination: prostate movements and dosimetric considerations[J]. Int J Radiat Oncol Biol Phys, 2005, 61 (2): 561-569.

共引文献70

同被引文献70

  • 1于金明,袁双虎.图像引导放射治疗研究及其发展[J].中华肿瘤杂志,2006,28(2):81-83. 被引量:99
  • 2胡选民.肿瘤放射治疗物理学[M].北京:原子能出版社,1999:9.
  • 3van Herk M,Remeijer P,Lebesgue JV.Inclusion of geometrical uncertainties in treatment plan evaluation[J].Int J Radiat OncoI Biol Phys,2002,52(5):1407-1422.
  • 4van Herk M.Errors and margins in radiotherapy[J].Semin Radiat Oncol,2004,14(1 ):52 -64.
  • 5Baiter JM,Chen GT,Pelizzari CA,et al.Online repositioning during treatment of the prostate: a study of potential limits and gains[J].Int J Radiat Oncol Biol Phys,1993,27(1):137-143.
  • 6Wu Q J, Li T, Wu Q, et al. Adaptive radiation therapy : technical components and clinical applications [ J ]. Cancer J , 2011, 17 (3) : 182 -9.
  • 7Jadon R, Pembroke C A, Hanna C L, et al. A systematic review of organ motion and image-guided strategies in external beam ra- diotherapy for cervical cancer [ J ]. Clin Oncol (R Coil Radiol ), 2014, 26(4) : 185 -96.
  • 8van de Bunt L, Jurgenliemk-Schulz I M, de Kort G A, et al. Mo- tion and deformation of the target volumes during IMRT for cervical cancer: what margins do we need[ J]. Radiother Oncol, 2008, 88 (2) : 233 -40.
  • 9Tanderup K, Georg D, Potter R, et al. Adaptive management of cervical cancer radiotherapy[J]. Semin Radiat Oncol, 2010, 20 (2) : 121 -9.
  • 10Bondar M L, Hoogeman M S, Mens J W, et al. Individualized nonadaptive and online-adaptive intensity-modulated radiotherapy treatment strategies for cervical cancer patients based on pretreat- ment acquired variable bladder filling computed tomography scans [J]. Int J Radiat Oncol Biol Phys, 2012, 83(5) : 1617 -23.

引证文献7

二级引证文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部