期刊文献+

多层螺旋CT在宫内节育器异位诊断的应用价值 被引量:3

The Value of MultiSlice Spiral CT in the Diagnosis of Ectopic Intrauterine Contraceptive Device
原文传递
导出
摘要 目的探讨多层螺旋CT在宫内节育器(IUD)嵌顿、异位及其并发症诊断中的应用价值。方法对2010年1月至2012年4月在本院检查并治疗的26例IUD异位患者的临床及影像资料进行回顾性分析,并与术中所见进行对照。所有病例均行CT及超声检查,11例另行X线摄片。结果 26例中IUD嵌顿于子宫肌层10例,其中4例穿破浆膜层;16例异位于子宫外,其中9例位于盆腔内,4例嵌顿于肠壁,2例嵌顿于膀胱,1例位于右侧腹腔肋弓下。所有病例中异位IUD均手术取出,手术所见与CT诊断符合率为100%。结论多层螺旋CT不仅在IUD异位诊断方面可提供精确、直观、立体的图像,同时可对其并发症做出正确的术前评估。 Objective To evaluate the value of MSCT in the diagnosis of embedded and ectopic intrauterine contraceptive device(IUD).Methods 26 cases with ectopic IUD during 2010.1~2012.4 were selected,the CT manifestations and intraoperative findings of 26 cases were compared.All cases received MSCT and Ultrasound.11 cases received X-ray examination.Results Of 26 cases,there were 10 cases of ectopic IUD embedded in the womb muscle layer and ectopic IUD was perforated through the uterine serosa in 4 cases;There were 16 cases of ectopic IUD outside the uterus: 9 cases with ectopic IUD in the pelvic cavity,4 cases with ectopic IUD embedded in the intestinal wall,2 cases with ectopic IUD embedded in the bladde,1 case with ectopic IUD displaced around the intestine in the right abdomen and the arcus costarum.All patients received surgical treatment.The diagnosis accordance between intraoperative findings and CT reached 100%.Conclusion MSCT could provide accurate,intuitive,stereo images in diagnosis of ectopic IUD,also make the correct preoperative evaluation of the ectopic IUD complications.
出处 《临床放射学杂志》 CSCD 北大核心 2013年第1期93-95,共3页 Journal of Clinical Radiology
关键词 宫内节育器 异位 体层摄影术 X线计算机 Intrauterine contraceptive device Ectopia Tomography X-ray computed
  • 相关文献

参考文献6

二级参考文献27

  • 1张利萍,吴雅峰,张淼.三维超声检查宫内节育器应用分析[J].中华医学超声杂志(电子版),2005,2(3):172-173. 被引量:6
  • 2徐志华,邱毅,曲继英,赵淑芹.2000例宫内节育器B超观察定位[J].中国超声医学杂志,1996,12(6):67-68. 被引量:14
  • 3马培青,陈秀芬.B超诊断子宫内外节育器异位[J].中国计划生育学杂志,1996,4(5):304-305. 被引量:18
  • 4周永昌 郭万学.超声医学[M].北京:科学技术文献出版社,1991.789.
  • 5蓝琦.X线诊断基础[M].人民卫生出版社,1993.289.
  • 6吕恩范 高淑华.妇产科超声诊断图谱[M].人民卫生出版社,1992.191.
  • 7Lee A, Eppel W, Sam C, et al. Intrauterine device localization by three-dimensional transvaginal sonography. Ultrasound Obstet Gynecol, 1997,10(4) : 289-292,
  • 8Jurkovie D, Gruboek K. Three-dimensional ultrasound of the uterus. Sono Ace International, 1998,4(3) :20-29.
  • 9George B, Anna S, Alfred B, et al. Three-dimensional ultrasonography in gynecology. J Ultrasound Med, 2003,22 (6) : 1249-1269.
  • 10Hosli I, Holzqreve W, Tercanli S. Assessing the position of intrauterine devices with three-dimensional ultrasound. Ultraschall Med, 2001,22(2) :75-80.

共引文献35

同被引文献44

  • 1曹泽毅.中华妇产科学[M].北京:人民卫生出版社,2004.2170-2172.
  • 2Balci O, Mahmoud AS, Capar M, et al. Diagnosis and man- agement of intra-abdominal, mislocated intrauterine devices [J]. Arch Gynecol Obstet, 2010, 281(6): 1019-1022.
  • 3Boortz HE, Margolis D J, Ragavendra N, et al. Migration of in- trauterine devices: radiologic findings and implications for pa- tient care[J]. Radiographics, 2012, 32(2): 335-352.
  • 4Kaplanolu M, Btilbtil M, Ytice T, et ol. Mislocated extrauterine intrauterine devices: Diagnosis and surgical management[J]. J Turk Ger Gynecol Assoc, 2015, 16(2): 91-95.
  • 5Sengul O, Dilbaz B, Kavak D, et al. Surgical management of extrauterine mislocated intrauterine contraceptive devices and related risks[J]. J Obstet Gynaecol, 2014, 34(1): 70-73.
  • 6Mosley FR, Shahi N, Kurer MA. Elective surgical removal of migrated intrauterine contraceptive devices from within the peritoneal cavity: a comparison between open and laparo- scopic removal[J]. JSLS, 2012, 16(2): 236-241.
  • 7Adoni A, Ben Cbetrit A. The management of intrauterine de- vices following uterine perforation[J]. Contraception, 1991, 43 (1): 77-81.
  • 8Markovitch O, Klein Z, Gidoni Y, et al. Extrauterine mislo- cared IUCD: is surgical removal mandatory[J]. Contraception, 2002, 66(2): 105-108.
  • 9Phupong V, Sueblinvong T, Pruksananonda K, et al. Uterine perforation with Lippes loop intrauterine device-associated actinomycosis: a case report and review of the literature [J]. Contraception, 2000, 61(5): 347-350.
  • 10Pirwany IR, Boddy K. Colocolic fistula caused by a previ- ously inserted intrauterine device. Case report[J]. Contracep- tion, 1997, 56(5): 337-339.

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部