期刊文献+

连续流动分析法测定烟草中K^+和Cl~–的不确定度评定 被引量:2

Evaluation of Uncertainty of the Determination of Potassium and Chloride Ions in Tobacco by the Continuous Flow Method
下载PDF
导出
摘要 采用连续流动分析法测定烟草中钾离子和氯离子含量,分析了测量不确定度的主要来源如样品水分测量、萃取液体积、样品浓度等,对各不确定度度分量进行了评定和计算。当钾离子、氯离子含量分别为1.66%,0.61%时,扩展不确定度分别为0.04%,0.02%。提出了连续流动分析法测定烟草中钾离子和氯离子时保证结果准确可靠的措施。 Potassium and chloride ion content in the tobacco were determined by continuous flow analysis method. Resources of determination uncertanity such as water detection, extraction solution volume, sample concentration and so on were analysed. Uncertainty component was evaluated and calculated. The expanded uncertainty was 0.04% for potassium and 0.02% for chloride as potassium and chloride content were 1.66% and 0.61%, respectively. Measures were proposed to guarantee the accuracy of the results detected by continuous flow analysis method.
出处 《化学分析计量》 CAS 2013年第1期82-85,88,共5页 Chemical Analysis And Meterage
关键词 连续流动分析法 烟草 K+ Cl– 不确定度评定 continuous flow analysis method tobacco K+ Cl- uncertainty evaluation
  • 相关文献

参考文献2

二级参考文献6

  • 1钱晓刚.施肥量和留叶数与烤烟产质的关系[M].贵州:贵州农学院丛刊,1997:47-52.
  • 2YC/T161-2002,烟草及烟草制品总氮的测定:连续流动法[S].北京:国家烟草专卖局,2002.
  • 3YC/T31-1996,烟草及烟草制品试样的制备和水分测定:烘箱法[S].北京:国家烟草专卖局,1996.
  • 4CNAS-CL01检测和校准实验室能力认可准则[S].2006.
  • 5JJF1059-1999.测量不确定度评定与表示[S].北京:中国标准出版社.1999.
  • 6CNAS-GL06.化学分析中不确定度的评估指南[S].,2006.133.

共引文献11

同被引文献23

引证文献2

二级引证文献9