期刊文献+

SOFA风对锅炉烟温偏差影响的数值模拟和试验研究 被引量:4

Numerical Simulation and Experimental Studies of SOFA Impact on Boiler Flue Gas Temperature Deviation
原文传递
导出
摘要 针对贵溪电厂600 MW超临界四墙切圆燃煤锅炉炉内左右两侧烟温偏差过大问题进行了数值模拟和试验研究。通过调整二次风和SOFA风风门开度,可以有效降低炉内两侧的烟温偏差,提高了锅炉运行的安全性和经济性。并对试验结果和模拟结果进行了综合分析,提出了较优的运行方式。 The numerical simulation and experimental studies on the left and right side Guixi Power Plant 600 MW supercritical four walls tangentially coal-fired boiler,but flue gas temperature deviation is too large.By adjusting the secondary air and the SOFA air damper opening,it can effectively reduce the furnace on both sides of the flue gas temperature deviation,this improves the safety and economy of the boiler operation.And conducting a comprehensive analysis of test results and simulation results,proposing optimum operating mode.
出处 《电站系统工程》 北大核心 2013年第1期21-23,共3页 Power System Engineering
关键词 四墙切圆燃烧锅炉 试验研究 烟温偏差 数值模拟 SOFA风 tangentially fired boiler experiment research temperature deviation numerical simulation SOFA