摘要 皮肤阻抗测量中,系统对激励源的质量要求很高。设计了一种基于AD9851和STC89C52的交变电流模式激励源。该激励源输出电流的幅值和频率在一定范围内可调,动态范围大,能用于人体皮肤阻抗的测量。试验表明,此激励源输出信号幅度和频率稳定性好,且输出阻抗高。 During the skin impedance measurement, the high quality of excitation source is critical to the measurement system. This paper designs a current mode excitation source based on the AD9851 and STC89C52 ,whose current amplitude and frequency can be adjusted in a certain range.It can be used in skin impedance measurement. Experiments show that the signal source has stable output signal amplitude and frequency, and high output impedance.
作者 严睿 陈新
出处 《数字技术与应用》 2012年第12期107-108,110,共3页 Digital Technology & Application
基金 福建省自然科学基金项目(项目编号:2012J01267)