期刊文献+

石墨炉原子吸收法测定空气滤纸中金属元素

Determination of the Metal Elements in Air Filter by Graphite Furnace Atomic Absorption Spectrometry
下载PDF
导出
摘要 目的:探讨一种检测空气滤纸中金属元素浓度的方法。方法:用微波消解法消解已知相关金属浓度的标准空气滤纸,用石墨炉原子吸收法测定标准空气滤纸中铅、镉、铬、锰等元素的浓度。结果:所选实验条件下,铅、镉、铬、锰的线性范围、检出限、精密度相对标准偏差和回收率分别为0-90、0-5、0-80、0-40μg/L;1.237、0.210、0.805、0.239μg/L;4.926%、4.774%、1.416%、6.451%;107.7%、94.5%、129.8%、103.7%。用该法测标准空气滤纸各元素的测定值和理论值很接近,相对误差均在允许范围之内。结论:该法简便快速、结果准确可靠,适于大规模空气滤纸样品金属浓度的检测。 Objective:To find a method for determining metal element content in standard filter by graphite furnace atomic absorption spectrometry(GFAAS).Methods:Standard filters which were known related metal content were diges-ted by microwave,and GFAAS was used to determine lead,cadmium,chromium and manganese in standard filter.Results:Under this condition,the linear range,detecting limit,relative standard deviation of precision and recovery rate of lead,cadmium,chromium and manganese were 0 ~ 90、0 ~ 5、0 ~ 80、0 ~ 40 μg/L,1.237、0.210、0.805、0.239 μg/L,4.926%、4.774%、1.416%、6.451%,107.7%、94.5%、129.8%、103.7%,respectively.Conclusion:This method is simple and rapid,accurate and reliable,and is suitable for large scale air sample heavy metal content detection.
出处 《汕头大学医学院学报》 2012年第4期199-201,共3页 Journal of Shantou University Medical College
基金 美国国立卫生研究院课题(1RC4ES019755-01)
关键词 原子吸收 标准空气滤纸 金属元素 atomic absorption standard air filter metal element